6.4
Commissioning
To activate the weighing system, press the
ON/
UNIT
OFF
button.
The operating temperature for the electronic system and the weighing cells will have
been reached after three to five minutes. . Prior to this, deviations of c. 0.3% are
possible.
Loads should not be lifted before this zero adjust is complete.
6.5
Overview of display
(
)
PRE-
PRINT
TOTAL
C
ZERO
NET
Max 200 kg
d = 0.2 kg
Max 500 kg
d = 0.5 kg
Max 2000 kg
d = 1 kg
ON/
UNIT
OFF
pcs/kg/lb
The seven displays provide the following information:
◄
The weighing system (incl. load) is stable
▬
The indicated weight has a negative value
ZERO
◄
the indicated weight is within the zero range
NET
◄
the indicated value is the net weight
▼
the indicated value is within the weighing range 1
▼
the indicated value is within the weighing range 2
▼
the indicated value is within the weighing range 3
VHT-BA-e-0910
10