KFB/KFN-TAM-BA_IA-e-1832
31
Press
; weighing system is in tolerance weighing mode.
From here evaluation takes place whether the goods to be
weighed are within the two tolerance limits.
Weighing with tolerance range
Set item weight, see chap. 7.10.
Tare when using a weighing container.
Put on goods to be weighed, tolerance control is started. The signal lights
indicate whether the load is within the two set limits.
Load below specified
tolerance
Load within specified
tolerance
Load exceeds specified
tolerance
Red signal light
next to „
-
“ ON illuminated
Green signal light
next to „
„ illuminated
Red signal light
next to „+“ ON illuminated
•
The tolerance control is not active when the weight is under 20d.
•
To delete limits, enter „00000 PCS“.