 OSF-4G-BA-e-1510 

12 

5.6  Using eye cups / High Eye Point eyepieces 

The  eye  cups  supplied  with  the  microscope  can  basically  be  used  at  all  times,  as 
they  screen  out  intrusive  light,  which  is  reflected  from  light  sources  from  the 
environment onto the eyepiece, and the result is better image quality. 

But  primarily,  if  eyepieces  with  a  high  eye  point  (particularly  suitable  for  those  who 
wear glasses) are used, then it may also be useful for users 

who don’t wear glasses, 

to fit the eye cups to the eyepieces. 

These  special  eyepieces  are  also  called  High  Eye  Point  eyepieces.  They  can  be 
identified  by  the  glasses  symbol  on  the  side.  They  are  also  marked  in  the  item 
description by an additional “H” (example: HSWF 10x Ø 23 mm). 

When fitting the eye cups, make sure that the dioptre setting is not moved. We would 
therefore  advise  that  you  hold  the  dioptre  adjustment  ring  on  an  eyepiece  with  one 
hand while you fit the eye cup with the other. 

Before  using  the  microscope,  users  who  wear  glasses  must  remove  the  eye  cups, 
which you may find on High Eye Point eyepieces. 

As  the  eye  cups  are  made  of  rubber,  you  must  be  aware  that  when  you  are  using 
them,  they  can  become  slightly  dirty  through  grease  residues.  In  order  to  maintain 
hygiene, we would therefore recommend that you clean the eye cups regularly (e.g. 
with a damp cloth). 

   Eye cups 

   High Eye Point eyepiece 

(identified by the glasses symbol) 

Summary of Contents for OSF 438

Page 1: ...N Sohn GmbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Stereo microscope KERN OSF 4G OSF 438 OSF 439...

Page 2: ......

Page 3: ...Assembly 8 5 Operation and functionality 10 5 1 Getting started 10 5 2 Adjusting the interpupillary distance 10 5 3 Adjusting the magnification 10 5 4 Dioptre adjustment and focussing 11 5 5 Adjusting...

Page 4: ...so the electrical parts in the base of the device must not be tampered with as in this area there is an additional risk of triggering an electric shock 1 2 Notes on the electrical system Before connec...

Page 5: ...older must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscope...

Page 6: ...s these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organ...

Page 7: ...OSF 4G BA e 1510 6 2 Nomenclature...

Page 8: ...ided left Product dimensions WxDxH 230x180x275 mm Standard configuration Model KERN Tube Eyepiece Field of view mm Objective Stand Illumination OSF 438 Binocular WF 10x 20 mm 20 1x 2x 3x mechanical 1W...

Page 9: ...e sure that you do not touch the optical lenses with your fingers In general you should avoid using two eyepieces with different magnifications When changing the eyepieces you must also loosen the sma...

Page 10: ...9 OSF 4G BA e 1510 Assembled stereo microscope...

Page 11: ...on uses the microscope the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthand or lefthand prism housing firmly By rotating...

Page 12: ...Then set the smallest possible zoom factor again 7 Then look through the lefthand eyepiece with the left eye with dioptre adjustment ring and bring the object into focus by turning the dioptre adjustm...

Page 13: ...ied by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved W...

Page 14: ...ng a microscope in its standard version the lighting is not suitable for the application then it often makes sense to fit an external lighting unit to overcome this problem The lighting units which ar...

Page 15: ...cal Service will be able to help 6 Optical data 7 Features Model outfit Kern model Order number OSF 438 OSF 439 Eyepieces WF 5x 16 2 mm OZB A4101 WF 10x 20 mm OZB A4102 WF 15x 15 mm OZB A4103 WF 20x 1...

Page 16: ...sufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The gap between the eyes is not set correctly The magnifications of th...

Page 17: ...materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...