1-2
BOP HIPWR 091719
1.2.1
LXI COMPATIBILITY (ME MODELS)
BOP with the ME suffix are designed to meet the LXI Version 1.4 standard, providing the follow-
ing standardized web interface capabilities for the user:
Discovery:
- MDNS (Bonjour - like the printer discovery)
- VXI-11 (National Instruments Ni Max, Agilent Io controller)
IP address support:
- DHCP
- AUTOIP
- Static IP (using Web Page)
Connections:
- SOCKET @ port 5025
- TELNET @ port 5024
Connection throughput:
- 25 milliseconds
NOTE: VXI-11 socket connection is provided for discovery. It only supports the *idn? query in
operation. Consult factory if this slow connection is required.
1.3
SPECIFICATIONS
Table 1-1 below indicates parameters that vary for different 1000 Watt BOP models; Table 1-2
lists general specifications that apply to all 1000 Watt BOP models.
TABLE 1-1. BOP 1000 WATT MODEL PARAMETERS
Model
d-c Output Range
Closed Loop Gain
Output Impedance
Voltage
(V d-c)
Current
(A d-c)
Voltage
Channel
G
V
(V/V)
Current
Channel
G
I
(A/V)
Voltage Mode
(Series R - L)
Current Mode
(Parallel R - C)
R
d-c
(mOhms)
L
(
H)
R
d-c
(Ohms)
C
(
F)
1000 WATT MODELS
BOP 6-125MG/ME
0 to ±6
0 to ±125
0.6
12.5
0.05
1.5
24
1150
BOP 10-100MG/ME
0 to ±10
0 to ±100
1.0
10.0
0.1
2.0
50
1100
BOP 10-75MG/ME
0 to ±10
0 to ±75
1.0
7.5
0.13
2.0
67
976
BOP 20-50MG/ME
0 to ±20
0 to ±50
2.0
5.0
0.40
8.3
200
371
BOP 25-40MG/ME
0 to ±25
0 to ±40
2.5
4.0
0.63
15.8
313
165
BOP 36-28MG/ME
0 to ±36
0 to ±28
3.6
2.8
1.30
25
640
103
BOP 50-20MG/ME
0 to ±50
0 to ±20
5.0
2.0
2.50
50
1250
55
BOP 72-14MG/ME
0 to ±72
0 to ±14
7.2
1.4
5.14
104
2570
33
BOP 100-10MG/ME
0 to ±100
0 to ±10
10.0
1.0
10.0
163
5000
16
NOTE: When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the
BOP. Otherwise the overvoltage protection will shut down the power supply.
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......