BOP HIPWR 091719
1-3
TABLE 1-2. BOP GENERAL SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
CONDITION
INPUT CHARACTERISTICS
a-c voltage
nominal
200/220/230/240Va-c
(1)
(200-240 Va-c)
No setting required. Single phase or between
2 phases of a 3-phase system within 200-
240Va-c.
range
176 - 264 Va-c
Continuous; Input voltage outside range
causes protection fault.
Frequency
nominal
50/60 Hz
range
47 - 63 Hz
Current
176 Va-c
9.5A (7.5A
(2)
)
maximum
264 Va-c
6.4A (4.4A
(2)
)
maximum
Power factor
Source
0.99 minimum
nominal output power
Sink
0.97 minimum
Efficiency
65% (56%
(2)
)
minimum when sourcing
Switching frequency, front end module
70 KHz ±5% (50KHz ±5%
(2)
)
Active PFC Input for both Source and Recu-
peration (Sink)
EMC Compliance
EN61326-1 (1997)
Class A equipment
EMC immunity to:
ESD
EN61000-4-2
Electrostatic discharge
Radiated RF
EN61000-4-3
EFT
EN61000-4-4
Electrical fast transient/burst
Surges
EN61000-4-5
Conducted RF
EN61000-4-6
EMC emissions
Conducted
EN61000-3-2
harmonics
EN61000-3-3
fluctuation & flicker
Conducted
EN55011/CISPR11
0.15 to 30 MHz
Radiated
EN55011/CISPR11
30 to 1000 MHz
Leakage current
3.5 mA
230V a-c, 47-63 Hz
Insulation coordination
Input
Installation Category II
For TN or TT power system
Overvoltage Category II
Output
Installation Category II
Maximum 300V (500V for BOP 10-100MG/
ME) common mode voltage between output
terminals and chassis ground.
Overvoltage Category II
Pollution degree
2
OUTPUT CHARACTERISTICS
(3)
Type of stabilizer
Voltage-current, 4-quadrant
Switch mode
Switching frequency, output module
100KHz ±5%
Output Stage
Source adjustment
range
voltage
-100% to +100% of rating
0 to 50 deg C
current
-100% to +100% of rating
Sink adjustment range
voltage
-100% to +100% of rating
0 to 50°C, recuperated energy is sent
back into line for general reuse
current
-100% to +100% of rating
(1) All specifications listed in this table are for 230V a-c input voltage.
(2) BOP 6-125MG/ME and BOP 10-75MG/ME only.
(3) Output characteristics are for a single standalone unit. Output characteristics of identical multiple unit parallel/series configurations
are described in the Technical Manual associated with the applicable Cable Kit (see Table 1-4).
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......