SUPERtrol II Flow Computer
113
Cause
Pulse output error detected
during service test run
Current output 1 error detected
during service test run
Current output 2 error detected
during service test run
Relay 1 error detected during
service test run
Relay 2 error detected during
service test run
RS-232 error detected during
service test run
Error detected in A/D converter
during self test
Error on access to the program
memory
All or part of the EEPROM data
for setup is damaged or has been
overwritten
The real time clock data was lost
during extended power outage
A display malfunction has been
detected.
Part or all of the internal RAM is
damaged
Steam trap malfunction
Steam trap malfunction
Contents of datalog were corrupt
and lost
Remedy
By Factory Service
By Factory Service
By Factory Service
By Factory Service
By Factory Service
By Factory Service
By Factory Service
By Factory Service
Re-Enter setup data,
If problem persists, Fac-
tory service required
Re-Enter time and date
By Factory Service
By Factory Service
Service steam trap
Change error delay
Clear datalog,
Clear errors
Error Message
PULSE OUT ERROR
Iout 1 ERROR
Iout 2 ERROR
RELAY 1 ERROR
RELAY 2 ERROR
RS-232 ERROR
A/D MALFUNCTION
PROGRAM ERROR
SETUP DATA LOST
TIME CLOCK LOST
DISPLAY
MALFUNCTION
RAM MALFUNCTION
TRAP ERROR
TRAP BLOWING
DATALOG LOST
Summary of Contents for SUPERtrol II