16
REMARKS
DISPLAY
PRESS
STEP
6
SETTING
THE
RELAYS
pre b
factor
count
rate
loc
relay
tot
or
preuu
b##.##
PRE A
Followed by
last PRE A
entered
PRE B
E N
E N
SETTING
THE
PRESETS
P R
This section sets up the relay information.
Press the PRGM key to choose TOT (Relay
B assigned to total) or PREW (Relay B as-
signed to prewarn). Press enter when the
desired choice is displayed.
This will only appear if
tot
selected. This is
the duration (.01 to 99.99 sec) that relay B
will remain energized. If 00.00 is selected,
the relay will latch until reset.
PRE A = Preset A (Batch Amount); The set
point at which output A will drop out after
started. If the displayed value is not the
desired preset, press the key(s) under the digit
to be changed.
PRE B = Preset B ;
a)
Tot
selected
The set point at which
output B will energize.
b)
preuu
selected The number of counts
before batch ends that
output B will drop out.
If the displayed value is not the desired preset,
press the key(s) under the digit to be changed.