12

OPERATION

A suitable pulse producing device or flow meter is wired to one of the three pulse inputs provided on the BAT R/T-M. 

Only one of these inputs is used in a given application. There are no connections to the two unused pulse inputs.

Isolated magnetic pickups may be connected to terminals 1 and 2. Isolated contact closures may be connected to 

terminals 5 and 6. Any high level, DC pulse type may be connected to terminals 9(-) and 10(+).

Power to the unit may be provided by internal batteries, external DC, or the current loop. In all cases, the internal 

battery will provide for continued operation in the event primary power is lost.

Once properly wired, the operation of the BAT R/T-M is automatic.

The flow totalizer is updated once per second* with battery power, 8 times per second with DC or loop power.   If no 

input counts are received the unit remains in a low power state to conserve power.

The flow total may be cleared by the front panel switch sequence or by a contact closure on the remote reset terminal 

to circuit common.

To reset the unit from the front panel, the following key sequence is required:

Press M   “CLr tot” will be displayed   (if the panel lock is on, the display will prompt "

ent code

".  

 

Enter the proper code to advance to the 

clr tot

 prompt)

Press E   To clear the total. Unit will return to operation

The flow rate indicator will measure the flow rate once every second* with battery power, 8 times per second with 

DC or loop power and display the flow rate. 

If the input pulses are not detected within the delay setting (0.1 to 99.9 seconds), a flow rate of 0 will be indicated.

The analog output will be scaled based on the user selected zero and full scale and the measured flow rate. The 

analog output is updated at the same time as the rate display.  

The pulse output updates at the same rate as the total display in accordance with the instrument setup of pulse 

scaling.

* Slow input pulse rates, large delay setting and internal math operations may delay the update rate of information.. 

A faster update rate occurs when the unit is loop powered or externally powered.

Summary of Contents for BAT R/T Millennium-S1

Page 1: ...Ratemeter Totalizer with RS232 Serial Port Installation and Operating Instructions 99982 11 10 15 KESSLER ELLIS PRODUCTS 10 Industrial Way East Eatontown NJ 07724 800 631 2165 732 935 1320 Fax 732 935...

Page 2: ......

Page 3: ...Installation and Replacement 3 Dimensions 4 Theory of Operation 5 Wiring 5 Typical Applications 5 Definitions 6 Programming Flowchart 9 Operation 12 Error Messages 13 Analog Output Calibration 13 War...

Page 4: ......

Page 5: ...MOSPHERE DE C DE GROUPE AVERTIR BOUCHER LES ENTREES INUTILISEES DE CONDUIT AVEC UN BOUCHON DE CONDUIT CERTIFIE ENVIRONMENTAL OPERATING TEMPERATURE 4 F 20 C to 158 F 70 C Extended Temp 22 F 30 C to 158...

Page 6: ...battery life by 20 IDATA STORAGE Setup Information Stored in flash memory Totalizer Stored in battery backed RAM but can be saved to flash memory by operator for recall after battery change out COMMU...

Page 7: ...iptor BAT illuminates when the battery voltage falls below this predetermined value The low battery detector operates correctly with all power options The battery or batteries should be replaced withi...

Page 8: ...RT M 0 BATRT M 1 E M 3 0120 DIAMETER 900 22 8 992 25 2 Mounting holes 125 Drill 2 places 438 Nylon Spacer Supplied 1 8 46 2 875 73 10 2 5 438 11 1 900 22 8 992 25 2 2 40 61 2 20 56 0 95 24 0 30 max 7...

Page 9: ...t frequency is used to access the table A linear interpolation of adjacent point pairs is used to arrive at the K Factor at that input frequency The flow rate and total are then computed based upon th...

Page 10: ...t is linear over its entire operating flow range Press the key to step to the desired choice Press the E key to enter the displayed factor type No yes set Pnts set 20 point This prompt allows the user...

Page 11: ...ay r deCloC ratemeter decimal location Sets the decimal location for the ratemeter information The ratemeter deci mal is not a dummy decimal and will scale the rate display accordingly i e if the r de...

Page 12: ...g display will result Pressing the M key will result in a display of an error mes sage E PULSE Press the E key to return to the run mode P uuidth pulse width Sets the pulse width of the pulse output S...

Page 13: ...ep the factor decimal to the desired location Press the E key to enter the displayed decimal location Press the M key to skip and keep the existing location NOTE For best performance and resolution ch...

Page 14: ...ress the E key to enter the displayed value Press the M key to skip and keep the existing value Press the key to increment each individual digit of the out high setting 20mA value This will only displ...

Page 15: ...setting Press the E key to enter the displayed lock setting Press the M key to skip and keep the existing setting Press the key to increment each individual digit of the lock code Press the key to ad...

Page 16: ...panel switch sequence or by a contact closure on the remote reset terminal to circuit common To reset the unit from the front panel the following key sequence is required Press M CLr tot will be displ...

Page 17: ...display an arbitrary total when new battery is installed In this case reset the total to 0 and check the setup information ANALOG OUTPUT CALIBRATION CAUTION Performing the analog output calibration wi...

Page 18: ...y 4 20 Point Linearization 10 point with S2 option D Rate per Day Hour or Minute ET Extended Temp 22 F to 158 F 30 C to 70 C CE CE Approved Version LVD EMC only CSA CSA Approved Version explosion proo...

Page 19: ...15 Revision History 03 09 05 Original release 11 10 15 Added Specifications and Dimensions for 3NE and 3SS mounting options...

Reviews: