background image

KEOFITT A/S

Kullinggade 31

DK-5700 Svendborg

Denmark

Phone +45 6316 7080

Fax +45 6316 7081

[email protected]

www.keofitt.dk

Keofitt reserves the right to change technical data without notice!

For complete set of updated data sheets and manuals for Keofitt products please refer to our web page www.keofitt.dk

Summary of Contents for STEAM BOILER

Page 1: ...D O N T G A M B L E W I T H Y O U R S A M P L E STEAM BOILER User Manual ...

Page 2: ... previous versions of this User Manual and states the major changes between versions This version list is introduced in December 2016 Version Version date Major changes from previous versions 1 1th December 2016 Complete revision and new layout ...

Page 3: ...Steam Boiler YEAR OF INTRODUCTION 2016 YEAR OF REVISED DESIGN 2016 LAST UPDATED 2016 The English version of this Manual is the governing version and it is the only authorized version Consequently KEOFITT cannot be held liable for other versions including translations of this Manual ...

Page 4: ...CONTENTS 1 PORTABLE STEAM CLEANING UNIT FOR CLEANING SAMPLE VALVES 5 2 PORTABLE MICRO BURNER 6 3 HOW TO USE 7 ...

Page 5: ...contents of the product being sampled IMPORTANT Microorganisms have different lethality depending on temperature and exposure time The steam produced in the Steam Boiler is not pressurized so the steam temperature is only around 100 C 212 F Make sure that the type and level of critical microorganisms in your application are such that steam at 100 C 212 F will suffice Part of the cleaning and disin...

Page 6: ... burner holds 30 grams of butane when fully refueled which burns for 35 60 minutes depending on flame intensity The output of this laboratory burner reaches 2500 BTU hour and it boils a 250 ml beaker of water in about five minutes It generates a flame temperature of up to 2200 F or 1200 C Fuel butane Fuel capacity 30 grams 50 ml Maximum burn rate up to 0 9 grams minute Burn time about 35 minutes a...

Page 7: ... with the burner gas control knob and take to your sample point STEAMING THE VALVE Hook the handle over the valve and connect the hose to the top port of the valve Consult the KEOFITT Sampling Valve Manual for full instructions on steaming and sampling Start the burner and bring the water back up to steam which should only take a few moments depending on the time since the tank was heated Steam th...

Page 8: ... USING GLOVES PROTECTIVE GLASSES AND PROPER ATTIRE TAKING ALL NECESSARY PRECAUTIONS 1 FILL BUTANE INTO BURNER PORT 2 REMOVE TOP FILL PLUG FILL WATER INTO STEAMER FILL PORT 100 TO 400 mL REPLACE PLUG 3 TURN GAS CONTROL ON USE TO TURN BURNER ON AND OFF AND CONTROL FLAME HEIGHT AND INTENSITY 4 PRESS IGNITER LEVER TO LIGHT BURNER PRELIMINARY ...

Page 9: ...k Phone 45 6316 7080 Fax 45 6316 7081 info keofitt dk www keofitt dk Keofitt reserves the right to change technical data without notice For complete set of updated data sheets and manuals for Keofitt products please refer to our web page www keofitt dk ...

Reviews: