TS-590S
71
ADJUSTMENT
Receiver Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
• Perform the following in the adjustment mode. Item 4 and 8~22.
To terminate the adjustment menu in the middle, save your settings with Menu No. 60.
1. Trap
frequency
(E type only)
•
15.5MHz
1) Display f.: 15.501MHz
Mode:
USB
PRE-AMP:
ON
Tracking
generator
Spectrum
analyzer
Rear
panel
TX-RX
(A/2)
ANT 1
CN201
TX-RX
(A/2)
TC102 Adjust TC102 to
get a null point
at 15.501MHz as
shown.
15.501MHz
• 11.7MHz
2) Display f.: 11.700MHz
Mode:
USB
PRE-AMP:
ON
TC101 Adjust TC101 to
get a null point at
11.7MHz as shown.
Repeat the trap
frequency adjust-
ment 2 to 3 times,
alternating between
15.5MHz and
11.7MHz.
11.7MHz
2. HF BPF
1) Display f.: 7.200MHz
Mode:
USB
PRE-AMP:
ON
L133
L150
L167
Adjust the coils to
obtain the frequency
response as shown.
6.9MHz 7.5MHz
2) Display f.: 14.200MHz
Mode:
USB
PRE-AMP:
ON
L134
L153
L168
K type
13.9MHz 14.5MHz
E type
13.9MHz 14.5MHz
3. IF Trap
(73.095MHz)
1) Display f.: 50MHz
Mode:
USB
PRE-AMP:
ON
L135
Adjust L135 at
73.095MHz to mini-
mum level.
73.095MHz