Test-
equipment
Unit
Terminal
Unit
Parts
Method
9. Carrier point
(XF473
10.695M
/2.7k)
1) Menu No.: 00 (1.81MHz, USB)
AGC:
OFF
SSG1 f.: 1.81010MHz
SSG2 f.: 1.81290MHz
SSG
output:
–33dBm (5.01mV)
SSG1
SSG2
2 signal pad
Oscilloscope
Rear
panel
TX-RX
(A/2)
ANT 1
TP2
(CAR)
Front
panel
[
] or
[
]
Change the adjust-
ment values to get
the waveform as
shown.
OK
NG
10. Carrier point
(XF474
11.374M
/2.7k)
1) Menu No.: 01 (1.81MHz, USB)
AGC:
OFF
SSG1 f.: 1.81010MHz
SSG2 f.: 1.81290MHz
SSG
output:
–33dBm (5.01mV)
11. Carrier point
(XF475
11.374M
/500)
1) Menu No.: 02 (1.81MHz, CW)
AGC:
OFF
SSG1 f.: 1.80970MHz
SSG2 f.: 1.81030MHz
SSG
output:
–33dBm (5.01mV)
12. AGC start
level (11M)
1) Menu No.: 03 (14.2MHz, USB)
SSG f.: 14.201MHz
SSG
output:
–110dBm (0.707µV)
SSG
Oscilloscope
AF V.M
DM.SP
Rear
panel
ANT 1
EXT.SP
Adjust data until the
display shown “1 to
2”.
13. AGC start
level (73M)
•
14M
1) Menu No.: 04 (14.2MHz, USB)
SSG f.: 14.201MHz
SSG
output:
–110dBm (0.707µV)
14. HF SSB
S-meter
•
S1
1) Menu No.: 08 (14.2MHz, USB)
SSG f.: 14.201MHz
SSG output: –107dBm (1µV)
Set the SSG, then
press the [
] or
[
] key.
S-meter lights up to S1 posi-
tion.
• S9
2) Menu No.: 09 (14.2MHz, USB)
SSG
output:
–81dBm (19.9µV)
S-meter lights up to S9 posi-
tion.
• Full scale
(Lights up
all)
3) Menu No.: 10 (14.2MHz, USB)
SSG
output:
–21dBm (19.9mV)
S-meter lights up all.
15. HF FM
S-meter
•
S1
1) Menu No.: 11(29.2MHz, FM)
SSG f.: 29.200MHz
SSG
output:
–117dBm (0.316µV)
MOD:
1kHz
DEV:
3kHz
S-meter lights up to 1dot posi-
tion.
• Full scale
(Lights up
all)
2) Menu No.: 12 (29.2MHz, FM)
SSG
output:
–95dBm (3.98µV)
S-meter lights up all.
16. HF FM
SQL thresh-
old
1) Menu No.: 13 (29.2MHz, FM)
SSG output: OFF
MOD:
1kHz
DEV:
3kHz
17. HF FM
SQL tight
1) Menu No.: 14 (29.2MHz, FM)
SSG f.: 29.200MHz
SSG
output:
–113dBm (0.501µV)
MOD:
1kHz
DEV:
3kHz
18. AGC start
level (73M)
•
50M
1) Menu No.: 15 (50.2MHz, USB)
SSG f.: 50.201MHz
SSG
output:
–114dBm (0.4µV)
Adjust data until the
display shown “1 to
2”.