TS-590S
78
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
20. Power PGC
•
50W
1) Menu No.: 50 (14.1MHz, CW)
Transmit
Power meter
150W ATT
Rear
panel
ANT 1
Front
panel
[
] or
[
]
Set the adjustment
value to become the
specifi ed ALC meter.
ALC meter 15 dots
• 25W
2) Menu No.: 51 (14.1MHz, CW)
Transmit
• 10W
3) Menu No.: 52 (14.1MHz, CW)
Transmit
• 5W
4) Menu No.: 53 (14.1MHz, CW)
Transmit
21. FM devia-
tion
•
Wide
1) Menu No.: 54 (29.1MHz, FM)
Transmit
Power meter
Linear
detector
150W ATT
4.1kHz
According to the
, –.
±0.1kHz
• Narrow
2) Menu No.: 55 (29.1MHz, FM)
Transmit
2.1kHz
According to the
, –.
±0.1kHz
22. Current
protection
1) Menu No.: 56 (24.9MHz, USB)
Transmit
DC power supply
DC IN:
DC 15.9V
Ammeter
Set the adjustment
value within the limit
of the specifi ed cur-
rent.
21.0A±0.1A
23. SWR pro-
tection
1) Menu No.: 57 (14.1MHz, CW)
Transmit
DC power supply
DC IN: DC 13.8V
150
Ω
dummy connection
: Use a cable that is 1m long
150
Ω
dum-
my load
Through
type power
meter
Set the adjustment
value within the
limit of the specifi ed
power.
40W±1W
24. SWR me-
ter
•
14M
(SWR: 3)
1) Menu No.: 58 (14.1MHz, CW)
Transmit
DC power supply
DC IN: DC 13.8V
150
Ω
dummy connection
: Use a cable that is 1m long
[
]
1 push
SWR meter lights up to 3
position.
• 50M
(SWR: 3)
2) Menu No.: 59 (51.9MHz, FM)
Transmit
DC power supply
DC IN: DC 13.8V
150
Ω
dummy connection
: Use a cable that is approx.
18cm long
• Writing data : After items 2~24 have been adjusted;
1) Menu No.: 60
2)
[
] or [
] key: Push once time. Display “rEAdy”
→
“good” (If “nG” is displayed, enter data again.)
3) [CLR] key: Push once time.
25. AT detec-
tion balance
1) Display f.: 51.9MHz
Mode:
FM
Power:
10W
Transmit
Oscilloscope
Power meter
150W ATT
Final
(A/2)
TP3
(AMP)
Final
(A/2)
VR5
Turn the VR5 to the
point where the
waveform on the os-
cilloscope changes
from high to low.
(Threshold point)