42
Concerning the received frequency display, an unmodulated signal may be
received. This is according to the set intrinsic frequency form.
<A band>
<B band>
VxU reception
(144 MHz + 45.05 MHz) x 2 – (430 MHz - 49.95 MHz)
= 45.05 MHz, 49.95 MHz
(144 MHz + 45.05 MHz) x 4 – (430 MHz - 49.95 MHz) x 2 = 45.05 MHz, 49.95 MHz
UxV reception
(430 MHz - 45.05 MHz)
– (144 MHz + 49.95 MHz) x 2 = 45.05 MHz, 49.95 MHz
(430 MHz - 45.05 MHz) x 2
– (144 MHz + 49.95 MHz) x 4 = 45.05 MHz, 49.95 MHz
Problem
Probable Cause
Corrective Action
“MCP ERR” appears on
the display. (MCP-2A
communications error)
1
Ensure that the
connection between
the TM-D710 and the
PC is correct.
2
While performing
a large amount of
processing on the
PC.
3
EchoLink mode turns
ON.
4
There are other
reasons why
communications was
not possible.
1
Checking connection
2
Shut down other software
that you may be running.
3
Turn EchoLink mode OFF.
4
Turn the TM-D710 power
source OFF and ON, one
time.
Summary of Contents for TM?D710