![background image](http://html.mh-extra.com/html/kenwood/tm-d710/tm-d710_instruction-manual_191775011.webp)
5
Black (—)
cable
Red (+)
cable
DC power cable
Fuse holder
(K, M4 types)
Fuse holder
(E type)
Fuse holder (E type)
Fuse holder
(K, M4 types)
Regulated DC
power supply
n
Power cable connection
In order to use this transceiver for fixed station operation, you will need a
separate 3.8 V DC power supply that must be purchased separately. The
recommended current capacity of the power supply is 3 A.
Note:
Do not plug the DC power supply into an AC outlet until you make all connections.
1
Ensure that the transceiver and DC power supply are both OFF.
2
Connect the DC power cable to the regulated DC power supply and ensure
that the polarities are correct (Red: positive, Black: negative).
• Use the supplied DC power cable to connect the transceiver to a regulated
power supply. Do not directly connect the transceiver to an AC outlet.
• Do not substitute the cable with smaller gauge wires.
3
Connect the DC power cable to the transceiver.
• Press the connectors firmly together until the locking tab clicks.
Note:
For your transceiver to fully exhibit its performance capabilities, we recommend using
an optional PS-33 (20.5 A, 25% duty cycle) power supply.
Summary of Contents for TM?D710