TK-7360/7360H/7360H
(
V
)
58
To make measurements in the RF section, connect the RF level meter.
In the RF section, use a 0.01μF coupling capacitor.
(The display shows the SSG input value required to obtain 12dB SINAD.)
To make measurement in the AF section, connect the AC level meter.
(ANT input: –53dBm, 1kHz FM, 3kHz Dev (WIDE))
The AF output level is adjusted for a 0.47V/4
Ω
by the front panel AF VOL control.
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz (Wide) DEV at 1kHz MOD.
To make measurements in the RF section, connect the RF Wattmeter (50
Ω
).
ANT
BPF
BPF
RF AMP
Q511
Mixer
Q507
MCF
XF500
FM IC
IC500
38.85MHz
CF500
450kHz
16
9
IC706
J701
16
26
AF Frequency (1kHz)
1
10
0.57Vrms
12mVrms
4.2mVrms 0.47Vrms
IC702
Baseband
IC
IC702
Baseband
IC
17
16
0.256Vrms
Center Frequency
IF AMP
Q504
W: –121dBm
W: –121.5dBm
W: 153.6mVrms
W: 61.2mVrms
W: 61.2mVrms
W: –106dBm
W: –106.5dBm
W: –103dBm
W: –119.5dBm
W: –91dBm
W: –95dBm
0.18Vrms
IC701
IC702
IC702
Q6
Q12
Q13
–12dBm
Display Unit
X54-374
TX-RX Unit
G1
D
G1
D
2
1
21
20
21 24
Q300
IC300
D17
ANT
50
Ω
D303
D304
TX-RX Unit (VCO)
TX-RX Unit
Power Module
TX-RX Unit
MIC
5.4dBm
6.2dBm
17dBm
25W
(TK-7360)
50W
(TK-7360H/
7360H(V))
3dBm
23dBm
1
4
LEVEL DIAGRAM
Receiver Section
T
ransmitter Section