TK-7360/7360H/7360H
(
V
)
34
• Signaling
Signaling
No.
RX (Decode)
TX (Encode)
1
None
None
2
None
20Hz Square Wave
4
QT: 67.0Hz
QT: 67.0Hz
5
QT: 151.4Hz
QT: 151.4Hz
6
QT: 210.7Hz
QT: 210.7Hz
7
QT: 254.1Hz
QT: 254.1Hz
8
DQT: D023N
DQT: D023N
9
DQT: D754I
DQT: D754I
10
DTMF (CODE: 159D)
DTMF (CODE: 159D)
11
None
DTMF (CODE: 9)
12
None
MSK (1010..)
13
FleetSync: 100-1000
Fleet Sync: 100-1000
14
None
Single Tone (1000Hz)
15
2-tone
(A: 304.7Hz, B: 3106.0Hz)
2-tone
(A: 304.7Hz, B: 3106.0Hz)
16
None
Single Tone (1477Hz)
17
Single Tone (979.9Hz)
Single Tone (979.9Hz)
18
None
MSK PN9
Panel Tuning Mode
■
Preparations for tuning the transceiver
Before attempting to tune the transceiver, connect the
unit to a suitable power supply.
Whenever the transmitter is turned, the transceiver must
be connected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with
a 4
Ω
dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
■
Transceiver tuning
(To place transceiver in tuning mode)
Press [ ] key, now in tuning mode. Use [
] key to write
tuning data through tuning modes, and [ ]/[ ] to adjust tun-
ing requirements (1 to 70/256/1024/4096 appears on LCD).
Use [
] key to select the adjustment item through tun-
ing modes. Use [ ] key to adjust 5 reference level adjust-
ments, and use [ ] key to switch between Wide/Narrow.
Channel appears on LCD. Set channel according to tun-
ing requirements.
• LCD display in panel tuning mode
S Q L
0
1
2 4
Adjustment item
Adjustment value
Wide
5 reference level
Narrow
: Low
: Low’
: Center
: High’
: High
■
Key operation
Key
Function
Push
Hold (1 second)
[ ]
End of panel tuning mode
-
[ ]
To enter 5 reference level
adjustments
-
[
]
Writes the adjustment
value
-
[
]
Go to next adjustment
item
Back to last adjustment
item
[ ]/[ ]
Adjustment value up/down Continuation up/down
[ ]/[ ]
Volume level up/down
Continuation up/down
[ ]
Squelch on/off
-
[ ]
Selects Narrow, Wide
-
■
5 reference level adjustments frequency (MHz)
TEST CH
RX
TX
Low
136.05000 136.10000
Low’
145.55000 145.50000
Center
155.05000 155.10000
High’
164.55000 164.50000
High 173.95000
173.90000
■
Adjustment item and Display
(
∗∗∗
1: 1~1024,
∗∗∗
4: 1~4048,
Only Frequency: 1~256, Only DQT: 1~70)
Order
Adjustment item
Display
1
RX Assist
RXASS
∗∗∗
1
2
TX Assist
TXASS
∗∗∗
1
3
Frequency
FREQ
∗∗
2
4
High Power
HPOW
∗∗∗
1
5
Mid Power
MPOW
∗∗∗
1
6
Low Power
LPOW
∗∗∗
1
7
DQT Balance
BAL
∗
7
8
Max Deviation
DEV
∗∗∗
4
9
DQT Deviation
DQT
∗∗∗
4
10
QT Deviation
QT
∗∗∗
4
11
DTMF Deviation
DTMF
∗∗∗
4
12
MSK Deviation
MSK
∗∗∗
4
13
Sensitivity (Semi-auto)
SENS1
∗∗∗
1
14
Sensitivity (Not used)
SENS2
∗∗∗
1
15
Squelch Open (5)
SQL
∗∗∗
1
16
Squelch tight
SQLT
∗∗∗
1
17
Low RSSI
LRSSI
∗∗∗
1
18
High RSSI
HRSSI
∗∗∗
1
ADJUSTMENT