TK-385
25
• Controls
Controls
“FNC” appears
“FNC” not appears
[PTT]
Used when making a
Used when making
transmission.
a transmission.
[AUX]
Release FNC
Unused
[Call]
Release FNC
Monitor ON and OFF.
[Clear]
Lamp ON/OFF
No Func
[A]
FFSK 1200bps
Sets to the Tuning
and 2400bps
mode.
[B]
Release FNC
FNC ON.
[C]
Compander function
RF power HIGH and
ON and OFF.
LOW.
[D]
Beat shift ON and OFF Changes signalling.
[O] to [9],
No Func
No Func
and [#], [
∗
]
[ENCODER] Release FNC
Changes channel.
ADJUSTMENT
Test Mode
■
Test mode operating features
This transceiver has a test mode.
To enter test mode, press
[B] key and turn power on. Hold [B] key until test channel
No. and test signalling No. appears on LCD. Test mode
can be inhibited by programming. To exit test mode, switch
the power on again. The following functions are available in
test mode.
• LCD indicator
“SCN”
Unused
“
”
Lights at Compander ON.
“LO”
Lights at RF Power Low.
“P”
Unused
“MON”
Lights at moniter ON.
“SVC”
Unlock
“ ”
Lights at FFSK 2400bps.
• LED indicator
Red LED
Lights during transmission. Blinks at the low
battery voltage warning.
Green LED
Lights when there is a carrier.
• Sub LCD indicator
“FNC”
appears at Function ON.
■
Frequency and signalling
The set has been adjusted for the frequencies shown in the
following table. When required. re-adjust them following the
adjustment procedure to obtain the frequencies you want in
actual operation.
Frequency (MHz) (K type)
Channel No.
RX frequency
TX frequency
1
455.05000
455.10000
2
440.05000
440.10000
3
469.95000
469.90000
4
460.00000
460.00000
5
460.20000
460.20000
6
460.40000
460.40000
7 ~ 16
Note
You must adjust the frequencies in all channels as shown
above, even though the channel frequencies in the 2 row are
below the specifications of the TK-385.
Signalling
Signalling No.
RX
TX
1
None
None
2
None
100Hz Square wave
3
QT 67.0Hz
QT 67.0Hz
4
QT 151.4Hz
QT 151.4Hz
5
QT 210.7Hz
QT 210.7Hz
6
QT 250.3Hz
QT 250.3Hz
7
DQT 023N
DQT 023N
8
DQT 754I
DQT 754I
9
None
DTMF tone 9
10
None
Single Tone 1600Hz
(HSD OUT)
11
None
Single Tone 1200Hz
(MODEM OUT)
12
None
Single Tone 1800Hz
(MODEM OUT)
13
None
FFSK(PN pattern)
14
FFSK(CODE)
FFSK(CODE)
• Preparations for tuning the transceiver
Before attempting to tune the transceiver, connect the unit
to a suitable power supply.
Whenever the transmitter is turned, the unit must be
connected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with a
16
Ω
dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
• Transceiver tuning
(To place transceiver in tuning mode)
Channel appears on LCD. Set channel according to tuning
requirements.