TK-380
9
OPERATING FEATURES
7) Revert Channel
The revert channel is used to transmit during scanning and
set by the programming software (KPG-60D).
1
Priority
The transceiver reverts to the priority channel
2
Priority with talkback
The transceiver reverts to the priority channel.
If you press PTT during a resume timer (dropout delay time,
TX dwell time) or calling, you can transmit on current
channel to answer to the call however revert channel is set
to priority channel.
After resume time, scan re-starts and transmission channel
is return to priority channel.
3
Selected channel
The transceiver reverts to the channel before scanning or
the channel that you changed during scan.
4
Last called channel
The transceiver reverts to the last called channel during
the scan.
5
Last used channel
The transceiver reverts to the last used (transmitted)
channel during scan. “Last used” revert channel includes
talkback function.
6
Selected with talkback
The transceiver reverts to the channel before scanning or
the channel that you changed during scan.
8) Scan End
When you reactivate the key programmed to the scan
function during scan mode, the scan ends.
The scan icon “SCN” and “-SCAN-” or revert channel
(programmable) display goes off.
9) Temporarily Delete/Add
It is possible to delete or add channel temporarily during
scan. When scan stops on unnecessary channel for example
by interference of the other party, activate the delete/add
function (for example press the key), then that channel is
deleted temporarily and scan re-start immediately.
When you would like to add the deleted channel temporarily
to scan sequence, select the desired (deleted) channel during
scan, activate the delete/add function (for example press the
key) before scan re-start.
That channel is added temporarily to scan sequence. The
temporary deleted or added channels are returns to pre-set
delete/add, when the transceiver exits from scan mode.
4. Details of Features
1) Time-out timer
The time-out timer can be programmed off or in 30 seconds
increments from 30 seconds five minutes. If the transmitter is
keyed continuously for longer than the programmed time, the
transmitter is disabled and a warning tone sounds while the
PTT button is held down. The alert tone stops when the PTT
button is released.
2) Sub LCD display
You can use 3-digit the display to display the channel
number or group number. It is useful when the main (12-digit)
display indicates, group or channel name or other functions.
3) Selective Call Alert LED
You can select whether or not the LED on the transceiver
flashes in an orange color when selective call was occurred.
4) PTT ID
PTT ID provides a DTMF or FFSK (DMS : Fleet-ID) ANI to
be sent with every time PTT (beginning of transmission, end
of transmission, or both).
You can program PTT ID “on” or “off” for each channel.
The contents of ID are programmed for each transceiver.
The timing that the transceiver sends ID is programmable.
BOT : DTMF ID (BOT)/FFSK ID is sent on beginning of
transmission.
EOT : DTMF ID (EOT)/FFSK ID is sent on end of
transmission.
Both : DTMF ID (BOT)/FFSK ID is sent on beginning of
transmission and DTMF ID (EOT)/FFSK ID is sent on end
of transmission.
5) Radio password
When the password is set in the transceiver, user can not
use the transceiver unless enter the correct password.
This code can be up to 6 digits from 0 to 9 and input with
the keypad or selector, and “CALL” key.
6) Minimum Volume
The minimum volume is programmable (off (0) to 31). The
transceiver remains the minimum volume level however the
mechanical volume position is set to zero.
7) "TOT" Pre-Alert
The transceiver has "TOT" pre-alert timer. This parameter
selects the time at which the transceiver generates "TOT" pre-
alert tone before "TOT" is expired.
"TOT" will be expired when the selected time passes from
a TOT pre-alert tone.
8) "TOT" Re-Key Time
The transceiver has "TOT" re-key timer. This timer is the
time you can not transmit after "TOT" exceeded. After "TOT"
re-key time expired you can transmit again.
Summary of Contents for TK-380