TK-380
50
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
Transmitter Section [Panel Tuning Mode except when Panel TEST Mode is specified.]
7. DQT Balance 1) Adj item [n BAL]
Power meter
Panel
ANT
Panel
Encoder
Make the
Adjust
Adjust [
∗∗∗
]
Dev meter
universal
knob
demodulation
[Narrow]
LPF:3kHz
Oscilloscope
connector
waves into
HPF:OFF
AG
square waves.
2) Adj item
AF VTVM
[nL BAL]
➞
[nC BAL]
➞
[nH BAL]
Adjust [
∗∗∗
]
PTT:ON
[Semi wide] 3) Adj item [s BAL]
Adjust [
∗∗∗
]
PTT:ON
[Wide]
4) Adj item [w BAL]
Adjust [
∗∗∗
]
PTT:ON
8. Max DEV
1) Adj item [n MAX]
1.85kHz
±
50Hz
Adjust
Adjust [
∗∗∗
]
(According to
[Narrow]
AG:1kHz / 150mV
the ,-)
Dev meter filter
LPF:15kHz
HPF:OFF
2) Adj item
[nL MAX]
➞
[nC MAX]
➞
[nH MAX]
Adjust [
∗∗∗
]
PTT:ON
[Semi wide] 3) Adj item [s MAX]
3.4kHz
±
50Hz
Adjust [
∗∗∗
]
(According to
PTT:ON
the ,-)
[Wide]
4) Adj item [w MAX]
4.20kHz
±
50Hz
Adjust [
∗∗∗
]
(According to
PTT:ON
the ,-)
9. MIC
[Panel Test Mode]
Check
1.2~2.0kHz
Sensitivity
1) CH-Sig: 1-1
Check
AG:1kHz / 8mV
LPF:15kHz
PTT:ON
10.QT Deviation 1) Adj item [n QT]
Panel
ANT
Panel
Encoder
0.35kHz
±
50Hz
Adjust
Adjust [
∗∗∗
]
universal
knob
LPF:3kHz
connector
HPF:OFF
[Narrow]
2) Adj item
[nL QT]
➞
[nC QT]
➞
[nH QT]
Adjust [
∗∗∗
]
PTT:ON
[Semi wide] 3) Adj item [s QT]
0.60kHz
±
50Hz
Adjust [
∗∗∗
]
PTT:ON
[Wide]
4) Adj item [w QT]
0.75kHz
±
50Hz
Adjust [
∗∗∗
]
PTT:ON
Summary of Contents for TK-380
Page 33: ...TK 380 33 PARTS LIST ...