![Kenwood TK-380 Service Manual Download Page 54](http://html.mh-extra.com/html/kenwood/tk-380/tk-380_service-manual_191510054.webp)
TK-380
54
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
2. Sensitivity
[Panel Test Mode]
SSG
Panel
ANT
Check
1) CH-Sig:1-1
AF VTVM
Universal
Check
12dB SINAD or
SSG OUT
Oscilloscope
connector
more
Wide:-118dBm (0.28
µ
V)
(MOD:1kHz /
±
3kHz)
Narrow:-117dBm (0.316
µ
V)
(MOD:1kHz /
±
1.5kHz)
3. Squelch
1) Adj item [n SQL]
Encoder
Adjust to point
(Preset)
Adjust [
∗∗∗
]
knob
of opening
Adjust
SSG OUT:
squelch.
[Narrow]
12dB SINAD level
2) Adj item
[nL SQL]
➞
[nC SQL]
➞
[nH SQL]
Adjust [
∗∗∗
]
[Semi Wide]
3) Adj item [s SQL]
Adjust [
∗∗∗
]
12dB SINAD level
4) Adj item
[sL SQL]
➞
[sC SQL]
➞
[sH SQL]
Adjust [
∗∗∗
]
[Wide]
5) Adj item [w SQL]
Adjust [
∗∗∗
]
12dB SINAD level
6) Adj item
[wL SQL]
➞
[wC SQL]
➞
[wH SQL]
Adjust [
∗∗∗
]
4. RSSSI
1) Adj item [n LRSI]
After input
(Low)
Adjust [
∗∗∗
]
signal from
Adjust
SSG OUT:
SSG,press
[Narrow]
12dB SINAD level
[D] key.
2) Adj item
That
[nL LRSI]
➞
[nC LRSI]
➞
[nH LRSI]
numeric will
Adjust [
∗∗∗
]
be stored
[Semi Wide]
3) Adj item [s LRSI]
in memory.
Adjust [
∗∗∗
]
12dB SINAD level
4) Adj item
[sL LRSI]
➞
[sC LRSI]
➞
[sH LRSI]
Adjust [
∗∗∗
]
[Wide]
5) Adj item [w LRSI]
Adjust [
∗∗∗
]
12dB SINAD level
6) Adj item
[wL LRSI]
➞
[wC LRSI]
➞
[wH LRSI]
Adjust [
∗∗∗
]
5. Squelch
[Panel Test Mode]
Check
Squelch must
(Preset)
1) CH-Sig:1-1
be opened.
Check
SSG OUT:
12dB SINAD level
2) SSG OUT:OFF
Squelch must
be closed.
Summary of Contents for TK-380
Page 33: ...TK 380 33 PARTS LIST ...