TK-378G
18
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
ADJUSTMENT
Receiver Section
Fig. 1 BPF-WAVE
M type
1. BPF
TEST CH : RX Center
Tracking generator
ANT
TC301, TC302,
Adjust wave form to figure 1.
Adjustment Tra-G setting -40dBm
Spectrum analyzer
BPF
TC303
2. Sensitivity
1) TEST CH : RX Center
SSG
ANT
Check
SSG OUT AF VTVM
Check
12dB SINAD or
Wide:-118dBm (0.28µV)
Oscilloscope
more
(MOD:1kHz / ±3kHz)
Narrow:-117dBm (0.316µV)
(MOD:1kHz / ±1.5kHz)
3. Squelch (Open) 1) TEST CH : RX Center
PC key
Adjust to the
Adjust
SSG OUT:
squelch
(PC MODE)
-123dBm (0.158µV)
threshold point
[Wide]
2) TEST CH : RX Center
[Narrow]
SSG OUT:
-122dBm (0.178µV)
4. Squelch(Tight) 1) TEST CH : RX Center
Adjust to the
Adjust
SSG OUT:-116dBm (0.35µV)
squelch
(PC MODE)
threshold point
[Wide]
[Narrow]
2) TEST CH : RX Center
SSG OUT:-115dBm (0.398µV)
5. Squelch
1) TEST CH : RX Center
Check
Squelch must
Check
SQ Level : [SQL5]
be opened.
(PC MODE)
SSG OUT:
-118dBm (0.28µV)
2) SSG OUT:OFF
Squelch must
be closed.