TK-378G
14
Common Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1. Setting
1) BATT terminal voltage:7.5V
2) SSG Standard modulation
[Wide] MOD:1kHz, DEV:3kHz
[Narrow] MOD:1kHz, DEV:1.5kHz
2. VCO lock
1) CH:RX High
Power meter
ANT
TC2
ADJ
4.0V ± 0.1V
voltage
2) CH:RX Low
DVM
CV(LV)
Check
0.8V or more
RX
TX
3) CH:TX High
TC1
ADJ
4.0V ± 0.1V
PTT:ON
4) CH:TX Low
Check
0.8V or more
PTT:ON
ADJUSTMENT
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1. Frequency
1) TEST CH:TX Center
Freq. Counter
ANT
VR1
Center frequency
Adjust
PTT:ON
± 100 Hz
2. High Power TEST CH: TX Low
Power meter
PC key
4.2W ± 0.1W
Check
TX Low’
Am meter
2.2A or less
Adjust
TX Center
(PC MODE)
TX High’
TX High
Battery terminal voltage:7.5V
PTT:ON
3. Low Power
TEST CH: TX Low
1.0W ± 0.1W
Adjust
TX Low’
1.0A or less
(PC MODE)
TX Center
TX High’
TX High
Battery terminal voltage:7.5V
PTT:ON
4. Max DEV
TEST CH: TX Low
Deviation meter
ANT
4.2kHz
±50Hz
Adjust
TX Center
Oscilloscope
SP/MIC connector
(According to
(PC MODE)
TX High
AG
the ,-)
[Wide]
AG:1kHz / 120mV
AF VTVM
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:TX Center
2.1kHz
PTT:ON
(According to
the ,-)
5. External
AG:20MHz (Square waves) /600mVpp
Deviation meter
ANT
VR3
Make the
CTCSS Input
Deviation meter filter
Oscilloscope
CN6(CT IN)
demodulation
Balance
LPF:15kHz
AG
waves into
Adjust
HPF:OFF
square waves.
M)151.0MHz
M4)143.0MHz
PTT:ON
6. QT TCXO
TEST CH: TX Low
Deviation meter
ANT
PC key
Balance
TX Center
Oscilloscope
SP/MIC connector
(PC MODE)
TX High
AG
[240] (Wide/Narrow)
AF VTVM
PTT:ON