TK-373G
28
ADJUSTMENT
Test Mode
■
Test mode operating features
This transceiver has a test mode. To enter test mode, press
the [
∞
] key and turn the power on. Hold the [
∞
] key until the
test channel No. and test signalling No. appear on LCD. Test
mode can be inhibited by programming. To exit test mode, switch
the power on again. The following functions are available in test
mode.
• Controls
[PTT]
Used when making a transmission.
[Side1]
Changes wide and narrow.
[Side2]
Monitor ON and OFF.
[A]
Sets to the Tuning mode.
[B]
Unused
[
∞
]
RF power HIGH and LOW.
[
5
]
Changes signalling.
[ENCODER] Changes channel.
• LCD indicator
“LO”
Lights at RF Power Low.
“MON”
Lights at monitor ON.
• LED indicator
Red LED
Lights during transmission. Blinks during low
battery voltage warning.
Green LED
Lights when there is a carrier.
Repair Jig (Extention Flat cable : part No.
E37-0851-05)
This cable is used for connecting the TK-373G display unit
and TX/RX unit when you test or repair the transceiver.
Caution :
You must connect TK-373G display unit when you
test or repair the transceiver.
Extention Flat cable
Display unit
TX/RX unit
■
Frequency and signalling
The set has been adjusted for the frequencies shown in the
following table. When required. re-adjust them following the
adjustment procedure to obtain the frequencies you want in
actual operation.
Frequency (MHz) (K type)
Channel No.
RX Frequency
TX Frequency
1
460. 05000
460. 10000
2
450. 05000
450. 10000
3
469. 95000
469. 90000
4
460. 00000
460. 00000
5
460. 20000
460. 20000
6
460. 40000
460. 40000
7~16
Frequency (MHz) (K2 type)
Channel No.
RX Frequency
TX Frequency
1
480. 05000
480. 10000
2
470. 05000
470. 10000
3
489. 95000
489. 90000
4
480. 00000
480. 00000
5
480. 20000
480. 20000
6
480. 40000
480. 40000
7~16
Signalling
Signalling No.
RX
TX
1
None
None
2
None
100Hz square wave
3
LTR DATA
LTR DATA
4
QT 67.0Hz
QT 67.0Hz
5
QT 151.4Hz
QT 151.4Hz
6
QT 210.7Hz
QT 210.7Hz
7
QT 250.3Hz
QT 250.3Hz
8
DQT D023N
DQT D023N
9
DQT D754I
DQT D754I
10
None
DTMF tone 9
• Preparations for tuning the transceiver
Before attempting to tune the transceiver, connect the unit
to a suitable power supply.
Whenever the transmitter is tuned, the unit must be
connected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with a
8
Ω
dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
• Transceiver tuning
(To place the transceiver in tuning mode)
Channel appears on the LCD. Set the channel according to
the tuning requirements.