background image

TK-3260EX

7

Test.Equipment.Required.for.Alignment

Test.Equipment

Major.Specifications

1.  Standard Signal Generator (SSG)

Frequency Range 

136 to 520MHz

Modulation 

Frequency modulation and external modulation

Output 

–127dBm/0.1µV to greater than –47dBm/1mV

2.  RF Power Meter

Input Impedance 

50

Ω

Operation Frequency 

136 to 520MHz

Measurement Range 

Vicinity of 10W

3.  Deviation Meter

Frequency Range 

136 to 520MHz

4.  Digital Volt Meter (DVM)

Measuring Range 

10mV to 10V DC

Input Impedance 

High input impedance for minimum circuit loading

5.  Oscilloscope

 

DC through 30MHz

6.  High Sensitivity 
 

Frequency Counter

Frequency Range 

10Hz to 1000MHz

Frequency Stability 

0.2ppm or less

7.  DC Ammeter

 

5A

8.  AF Volt Meter (AF VTVM)

Frequency Range 

50Hz to 10kHz

Voltage Range 

1mV to 10V

9.  Audio Generator (AG)

Frequency Range 

50Hz to 5kHz or more

Output 

0 to 1V

10.  Distortion Meter

Capability 

3% or less at 1kHz

Input Level 

50mV to 10Vrms

11.  Spectrum Analyzer

Measuring Range 

DC to 1GHz or more

12.  Tracking Generator

Center frequency 

50kHz to 600MHz

Output Voltage 

100mV or more

13.  16

Ω

 Dummy Load

 

Approx. 16

Ω

, 3W

14.  Regulated Power Supply

 

5V to 10V, approx. 3A

 

Useful if ammeter equipped

n

Antenna.connector.adapter

The  antenna  connector  of  this  transceiver  uses  an  SMA 

terminal.

Use  an  antenna  connector  adapter  [SMA(f)  –  BNC(f)  or 

SMA(f)  –  N(f)]  for  adjustment.  (The  adapter  is  not  provided 
as an option, so buy a commercially-available one.)

n

.Battery.Jig.(W05-157-00)

Connect the power cable properly between the battery jig 

installed in the transceiver and the power supply, and be sure 
output voltage and the power supply polarity prior to switch-
ing the power supply ON, otherwise over voltage and reverse 
connection may damage the transceiver, or the power supply 
or both.
Note: When  using  the  battery  jig,  you  must  measure  the 
voltage at the terminals of the battery jig. Otherwise, a slight 
voltage drop may occur within the power cable, between the 
power supply and the battery jig, especially while the trans-
ceiver transmits.

S

+

C1

100P/25V

C2

470P/25V

C3

100µ/25V

+

+Terminal

(Red)

–Terminal

(Black)

Power

supply

Power

cable

Schematic diagram

ADJUSTMENT

+ Terminal(Red)

- Terminal(Black)

Summary of Contents for TK-3260EX

Page 1: ...here fore void the intrinsic safety rating ATEX IECEx approved product may be repaired only by an ATEX IECEx approved Kenwood designated Authorized Service Center GENERAL 2 SYSTEM SET UP 3 REALIGNMENT 3 EXPLODED VIEW 5 PACKING 6 ADJUSTMENT 7 OPTION 13 SPECIFICATIONS 13 This product uses Lead Free solder This product complies with the RoHS directive for the European market ...

Page 2: ...imilar types of commercial grade com munications equipment It contains all required service information for the equipment and is current as of the publi cation date Changes which may occur after publication are covered by either Service Bulletins or Manual Revisions These are issued as required ORDERING REPLACEMENT PARTS When ordering replacement parts Please refer to pages 5and 6 PERSONAL SAFETY ...

Page 3: ...transceiver to the personal computer with the interface cable and USB adapter when the interface cable is KPG 36A the KCT 53U can be used Note You must install the KCT 53U driver in the computer to use the USB adapter KCT 53U When using the USB adapter KCT 53U for the first time plug the KCT 53U into a USB port on the computer with the computer power ON 2 When the POWER is switched on user mode ca...

Page 4: ...g the KCT 53U install the supplied CD ROM with driver software in the computer The KCT 53U driver runs under Windows 2000 or XP or Vista 32bit 3 5 FPU Programming Software Description The FPU is the programming software for the transceiver supplied on a CD ROM This software runs under Windows 2000 or XP or Vista 32bit The software on this disk allows a user to program the transceiver via Programmi...

Page 5: ...ODED VIEW Knob Volume Knob Selector 3 2 1 B A Escutcheon Packing Li ion Battery Cap Dressed Screw Belt Clip Screw K29 9408 03 K29 9407 03 B01 1102 03 B09 0712 03 KBH 16EX KNB 58LEX N08 0564 04 G53 1769 04 N09 2440 15 ...

Page 6: ...31 PACKING 3 2 1 D C Instruction manual B62 2227 10 Pamphlet Item carton case Packing fixture Belt clip KBH 16EX Li ion Battery KNB 58LEX Cap B09 0712 03 Packing Cap G53 1769 04 Dressed screw N08 0564 04 Sefety manual B62 2233 10 ...

Page 7: ... 12 Tracking Generator Center frequency 50kHz to 600MHz Output Voltage 100mV or more 13 16Ω Dummy Load Approx 16Ω 3W 14 Regulated Power Supply 5V to 10V approx 3A Useful if ammeter equipped nAntenna connector adapter The antenna connector of this transceiver uses an SMA terminal Use an antenna connector adapter SMA f BNC f or SMA f N f for adjustment The adapter is not provided as an option so buy...

Page 8: ...tone9 11 12 None Single Tone 1000Hz 13 None MSK 14 MSK Code MSK Code Preparations for Tuning the Transceiver Before attempting to tune the transceiver connect the unit to a suitable power supply Whenever the transmitter is tuned the unit must be con nected to a suitable dummy load i e power meter The speaker output connector must be terminated with a 16Ω dummy load and connected to an AC voltmeter...

Page 9: ... Wide 5k MOD 1kHz DEV 3kHz Wide 4k MOD 1kHz DEV 2 4kHz Narrow MOD 1kHz DEV 1 5kHz FPU 2 Receive Assist 1 TEST CH Low Power meter DVM ANT FPU 1 95V 0 5V 2 TEST CH Low 2 35V 3 TEST CH Center 2 65V 4 TEST CH High 3 05V 5 TEST CH High 3 35V 3 Transmit Assist 1 TEST CH Low PTT ON 2 05V 0 5V 2 TEST CH Low PTT ON 2 45V 3 TEST CH Center PTT ON 2 75V 4 TEST CH High PTT ON 3 05V 5 TEST CH High PTT ON 3 35V ...

Page 10: ... AF VTVM ANT SP MIC connector 4 2kHz According to the larger 4 0kHz High only 100Hz Wide 4k 2 TEST CH Center PTT ON 3 4kHz According to the larger 100Hz Narrow 3 TEST CH Center PTT ON 2 1kHz According to the larger 100Hz 4 VOX1 Writing 1 TEST CH Center AG 1kHz 60mV Power meter Deviation meter Oscilloscope AG AF VTVM ANT Write 5 VOX10 Writing 1 TEST CH Center AG 1kHz 4mV Write 6 DQT TCXO Balance Wr...

Page 11: ...enter PTT ON 0 35kHz 40Hz 10 Single Tone Fine Deviation Wide 5k 1 TEST CH Center Low High Deviation meter filter LPF 15kHz HPF OFF PTT ON 3 0kHz 100Hz Wide 4k 2 TEST CH Center PTT ON 2 4kHz 100Hz Narrow 3 TEST CH Center PTT ON 1 5kHz 100Hz 11 DTMF Fine Deviation Wide 5k 1 TEST CH Center Low High Deviation meter filter LPF 15kHz HPF OFF PTT ON 3 0kHz 100Hz Wide 4k 2 TEST CH Center PTT ON 2 4kHz 100...

Page 12: ...pen Wide 4k 2 TEST CH Center SSG output 12dB SINAD 1dB level SSG MOD 2 4kHz Narrow 3 TEST CH Center SSG output 12dB SINAD 0 5dB level SSG MOD 1 5kHz 3 Squelch Tight Writing Wide 5k 1 TEST CH Center Low High 3 points SSG output 12dB SINAD 4 5dB level SSG MOD 3 0kHz Wide 4k 2 TEST CH Center SSG output 12dB SINAD 4 5dB level SSG MOD 2 4kHz Narrow 3 TEST CH Center SSG otuput 12dB SINAD 4 5dB level SSG...

Page 13: ...eiver Measurements made per EN standard Sensitivity emf EIA 12dB SINAD 0 25μV 6dBµV Wide 5k 4k 0 32μV 4dBµV Narrow EN 20dB SINAD 0 32μV 4dBµV Wide 5k 4k 0 36μV 3dBµV Narrow Adjacent Channel Selectivity 70dB Wide 5k 4k 62dB Narrow Intermodulation Distortion 65dB Spurious Response 70dB Audio Output 400mW 16Ω Audio Distortion Less than 10 Transmitter Measurements made per EN standard RF Power Output ...

Page 14: ...oad Watford Herts Amsterdamseweg 37 1422 AC Uithoorn The Netherlands Via G Sirtori 7 9 20129 Milano Italy Bolivia 239 08020 Barcelona Spain Talavera Business Park Building A 4 Talavera Road North Ryde NSW 2113 Australia Unit 3712 3724 Level 37 Tower one Metroplaza 223 Hing Fong Road 1 Ang Mo Kio Street 63 Singapore 569110 CA 90801 5745 U S A Kwai Fong N T Hong Kong WD18 9EB United Kingdom Bp 58416...

Reviews: