TK-3260EX
10
ADJUSTMENT
Transmitter.Section
Item
Condition
Measurement
Adjustment
Specifications./.Remarks
Test.equipment
Terminal
Parts
Method
1. Frequency Adjust
1) CH: High
PTT: ON
f. counter
ANT
FPU
469.90050MHz
±50Hz
2. RF High
Power
1) TEST CH: Low, Low’, Center,
High’, High (5 points)
BATT terminal voltage: 7.5V
PTT: ON
Power meter
Ammeter
1.2W±0.05W
1.0A or less
3. Maximum
Fine
Deviation
[Wide 5k]
1) TEST CH:Center, Low, High
(3 points)
AG: 1kHz/150mV
Deviation meter filter
LPF: 15kHz, HPF: OFF
PTT: ON
Power meter
Deviation meter
Oscilloscope
AG
AF VTVM
ANT
SP/MIC
connector
4.2kHz (According
to the , –)
4.0kHz(High only)
±100Hz
[Wide 4k]
2) TEST CH: Center
PTT: ON
3.4kHz (According
to the , –)
±100Hz
[Narrow]
3) TEST CH: Center
PTT: ON
2.1kHz (According
to the , –)
±100Hz
4. VOX1
Writing
1) TEST CH: Center
AG: 1kHz/60mV
Power meter
Deviation meter
Oscilloscope
AG
AF VTVM
ANT
Write
5. VOX10
Writing
1) TEST CH: Center
AG: 1kHz/4mV
Write
6. DQT TCXO
Balance
Writing
[Wide 5k]
1) TEST CH: Center, Low, High
(3 points)
Write
150hex
[Wide 4k]
2) TEST CH: Center
[Narrow]
3) TEST CH: Center
7. DQT VCO
Balance
[Wide 5k]
1) TEST CH: Center, Low, High
(3 points)
Deviation meter filter
LPF: 3kHz, HPF: OFF
PTT: ON
Make the demod-
ulation wave into
square waves.
[Wide 4k]
2) TEST CH: Center
PTT: ON
[Narrow]
3) TEST CH: Center
PTT: ON