NXR-810
76
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
10. RSSI
Reference
Adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [RSSI Ref (Ana-
log Wide)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’]
[Center], [High’], [High]
Output
: 12dB SINAD level –1dB
MOD: 1.0kHz
DEV: ±3.0kHz
SSG
Audio
analyzer
Rear
RX ANT
PC
ADJ
Press [Apply] button to store
the adjustment value.
11. RSSI
Reference
Adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [RSSI Ref (Ana-
log Narrow)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’]
[Center], [High’], [High]
Output
: 12dB SINAD level –1dB
MOD: 1.0kHz
DEV: ±1.5kHz
12. RSSI
Reference
Adjust
[NXDN
Very
Narrow]
FPU Test mode
1) Adjust Item: [RSSI Ref (NXDN
Very Narrow)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’]
[Center], [High’], [High]
Output
: 12dB SINAD level –1dB
MOD: OFF
13. Low RSSI
Adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [Low RSSI (Ana-
log Wide)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’]
[Center], [High’], [High]
Output: –118dBm (0.28µV)
MOD: 1.0kHz
DEV: ±3.0kHz
SSG
Rear
RX ANT
PC
ADJ
Press [Apply] button to store
the adjustment value.
14. Low RSSI
Adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [Low RSSI (Ana-
log Narrow)]
Connect the SSG to the RX
ANT.
SSG
setting
Frequency: [Low], [Low’]
[Center], [High’], [High]
Output: –118dBm (0.28µV)
MOD: 1.0kHz
DEV: ±1.5kHz