17
KDC-BT6544U/BT6544UY
/BT7043U/BT742U
■
Backup current measurement
Procedure
Note
While ACC OFF (Back Up ON), Reset
MUTE terminal is OFF after 2 seconds, not after 15 seconds.
(During this time, the CD mechanism does not function.)
■
Switching of Preout
Procedure
Note
Press and hold [TEL/TI/AUTO] key in the Standby source
Switching PREOUT (1 Preout / 2 Preout model)
■
Clearing of CD mechanism information, Service information, DC offset error information, BT memory
information, and FAVORITE registration information. (Clear the data recorded in FLASH MEMORY of
E2PROM and BT module)
Status
Display
Description
Resetting while [TEL/TI/AUTO] + [FAV]
is being pressed
C
D
O
At normal termination
C
D
X
At abnormal termination
While “– – – –” is displayed, power can be ON. This mode is cancelled by resetting. (The last screen will not be retained.)
Data to be cleared is shown below.
Information to be cleared
Details of information
Data recorded in
CD mechanism informa-
tion
CD mechanism error log display
E2PROM
Displays CD loading error data
E2PROM
Displays CD EJECT error data
E2PROM
Displays CD time code count error data (missing count)
E2PROM
Displays CD time code count error data (count not updated)
E2PROM
Service Information
Power ON time display
E2PROM
CD operation time display
E2PROM
CD EJECT times display
E2PROM
PANEL open/close times display
E2PROM
Forced Power OFF information display
E2PROM
DC offset error informa-
tion
DC offset error 1 display (Provides information on whether there is an improper
connection or another error)
E2PROM
DC offset error 2 display (Provides information on the number of capacitor leaks)
E2PROM
BT memory information
Pairing information
FLASH memory in BT module
Preset phone number information
E2PROM
Friendly name (Setting)
FLASH memory in BT module
PIN code
FLASH memory in BT module
FAVORITE registration
information
FAVORITE registration information (Registration list)
* Total 10 items
E2PROM
TEST MODE