(No.WA063<Rev.003>)24/31
4.4
Service Information Clear Mode
Press and hold [2] key and [5] key and reset.
4.4.1 Default condition when the mode is started
It shall be same as normal activation.
4.4.2 Mode structure
Service Information Clear Mode can be executed independent of the current source.
4.4.3 Mode content
After entering this mode, Syscon shall clear the information stored for service and output the result to the display tube.
The following table shows the data that is cleared.
Display content
Details
Clearing DATA *1 Hz blinking
When normal end
When error end
Information for data clearing
Details
Storage area
CD mecha information
CD mecha log display
E2PROM
CD load error information display
E2PROM
CD eject error information display
E2PROM
CD time code error count information display (count skip)
E2PROM
CD time code error count information display (no count update)
E2PROM
Service information
CD EJECT number of times display
E2PROM
Force Power information display
E2PROM
DC error information
DC error 1 display (wrong connection & other detection information in de-
tecting duration)
E2PROM
DC error 2 display (capacitor leakage detection number information)
E2PROM
BT memory information
Pairing information
FLASH memory in the
BT module
Preset phone number information
E2PROM
Friendly Name (setting)
FLASH memory in the
BT module
PINCODE
FLASH memory in the
BT module
Phone book in the BT module
FLASH memory in the
BT module
MIC Gain
E2PROM
Delay data
E2PROM
Tagging information
Data of iTunes Tagging
E2PROM
Backup memory information
Tuner preset (Including Mixed Preset)
E2PROM
Pandora information
Pandora Preset
E2PROM
SXM memory information
Preset Channel SID
E2PROM
Preset Skip Channel SID
E2PROM
Parental Lock Code
E2PROM
Preset Locked Channel SID
E2PROM
D
A
T
A
R
C
L
D
A
T
A
R
O
K
:
C
L
D
A
T
A
L
C
R
N
G
: