DM-3090
26
ADJUSTMENT
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button three times.
RESULT sub-menu
[ _ R S T _ Y O B I _ ]
Step 3
Press once the MD PLAY button. Indication of measurement value
[ R F G : _
_ _
]
Step 4
Press once the ENTER button.
Indication of measurement value
[ R C G : _
_ _
]
Step 5
Press once the ENTER button.
Indication of measurement value
[ R T G : _ _ _ _ _
]
Step 6
Press once the ENTER button.
Indication of measurement value
[ G T G : _ _ _ _ _
]
Step 7
Press once the ENTER button.
Indication of measurement value
[ P C H : _ _ _ _
]
Step 8
Press once the ENTER button.
Indication of measurement value
[ G C H : _ _ _ _
]
Step 9
Press once the ENTER button.
Indication of measurement value
[ S A G : _ _ _
]
Step 10
Press once the ENTER button.
Indication of measurement value
[ S B G : _ _ _
]
Step 11
Press once the ENTER button.
Indication of measurement value
[ S E G : _ _ _
]
Step 12
Press once the ENTER button.
Indication of measurement value
[ S F G : _ _ _
]
Step 13
Press once the ENTER button.
Indication of measurement value
[ H A O :
_ _ _]
Step 14
Press once the ENTER button.
Indication of measurement value
[ H B O :
_ _ _]
Step 15
Press once the ENTER button.
Indication of measurement value
[ H E O :
_ _ _]
Step 16
Press once the ENTER button.
Indication of measurement value
[ H F O :
_ _ _]
Step 17
Press once the ENTER button.
Indication of measurement value
[ L A O :
_ _ _]
Step 18
Press once the ENTER button.
Indication of measurement value
[ L B O :
_ _ _]
Step 19
Press once the ENTER button.
Indication of measurement value
[ L E O :
_ _ _]
Step 20
Press once the ENTER button.
Indication of measurement value
[ L F O :
_ _ _]
Step 21
Press once the ENTER button.
Indication of measurement value
[ T C O : _
_ _ _]
Step 22
Press once the ENTER button.
Indication of adjustment error sequence No.
[ Y O B : _
_ _ _]
Step 23
Press once the ENTER button.
Indication of adjustment status
[ D I F : _
_ _ _]
Step 24
Press once the ENTER button.
Indication of pre-adjustment not completed (00)/completed (4B)
[ A D J : _
_ _ _]
Step 25
Press once the MD STOP button. RESULT sub-menu state
[ _ R S T _ Y O B I _ ]
3. RESULT sub-mode
Step No.
Setting Method
Remarks
Display
•
: Measurement value,
: Adjustment value,
: Other various informations
• ressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button four times.
RESULT menu
[ _ R S T U L T _ _ _ ]
Step 3
Press once the MD PLAY button. Indication of set value
[ H A G : _ _ _
]
Step 4
Press once the ENTER button.
Indication of set value
[ H B G : _ _ _
]
Step 5
Press once the ENTER button.
Indication of set value
[ L A G : _ _ _
]
Step 6
Press once the ENTER button.
Indication of set value
[ L B G : _ _ _
]
Step 7
Press once the ENTER button.
Indication of set value
[ P E G : _ _ _
]
Step 8
Press once the ENTER button.
Indication of set value
[ P F G : _ _ _
]
Step 9
Press once the ENTER button.
Indication of set value
[ G E G : _ _ _
]
Step 10
Press once the ENTER button.
Indication of set value
[ G F G : _ _ _
]
Step 11
Press once the ENTER button.
Indication of set value
[ G C G : _ _ _ _
]
Step 12
Press once the MD STOP button. RESULT menu state
[ _ R E S U L T _ _ _ ]
4. RESULT mode (final adjustment)
Step No.
Setting Method
Remarks
Display
•
: Measurement value
• ressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
DM-3090(K)
COVER
97.11.29
0:19
AM
y [ W
33
Summary of Contents for DM-3090
Page 31: ...DM 3090 31 PARTS DESCRIPTIONS ...