15
MAXIMUM USABLE POWER FOR THE COO-
KING ZONES
The right and left cooking zones are controlled by two
separate power boards and the maximum total power
per each power board is 3700 W.
Should the cooking zones of one power board require
more than 3700 W, the last selected power level has
priority and the power of the other cooking zone is au-
tomatically reduced to the remaining power available.
If this occurs, the cooking zone will display a flashing
figure for about 3 seconds before automatically display-
ing the new power level.
This means for example that:
•
When setting a “Booster” programme for the second zone, the setting for the other
zone could be reduced to the remaining power available.
•
When setting a “Booster” programme for a zone and then another setting on the se-
cond zone, if the total power exceed 3700 W the “Booster” programme is deleted and
the power reduced to the maximum power available.
THERMAL PROTECTIONS
The induction hob is fitted with safety devices to protect the electronic system and to pro-
tect each cooking zone from overheating.
In case of overheating, one of the following automatic functions could be started by the
electronic system:
•
“Booster” program deleted and power reduced;
•
one or more cooking zone switched Off;
•
cooling fan motor of the induction unit switched on.
CHILDLOCK SAFETY
When not using the induction hob, set the childlock safety to prevent children from acciden-
tally switching on the cooking zones.
Ensure all cooking zones are switched Off, then turn the control knobs of the left cooking
zones simultaneously to the left ( setting) and hold the knobs in this position until
lights
up on the cooking zones display; then release the knobs.
To deactivate the childlock repeat the same procedure until
lights up on the cooking
zones display; then release the knobs.
Controlled by
2nd power board
Controlled by
1st power board