33
FZDA07ELEF2/EREF2/MRHF2
■
Engineering Diag Menu (Page2) screen
N ex t
S e r v i c e 2
TEL Voice Set
HDD PassWord ON
BT RF TEST
Batch Prog.
HDD Information
Reset Position
A
B
C
D
G
H
L
1
F
●
Description of operations
1 Title
A Open the panel. (Only for ZR1) (Only for Japan
destination)
B
Run the batch program. (On Screen Display is shown.)
(Only for Japan destination)
C Shift to “Engineering Diag Menu (Page3)” screen.
D Shift to “HDD Information” screen. (Only for Japan
destination)
F
Shift to “HF Voice Quality Parameter” screen. (Only for
Japan destination)
G Shift to “BT RF Test” screen.
L
Turn ON/OFF “HDD password setup”. (Only for Japan
destination)
H Shift to “Reset Position” screen.
■
HDD Information screen
∗
This screen is available only in the Japan model.
Menu
HDD Information
Serial : 01234567890123456789
Now Temp : 25C
Past Highest Temp/Date
:
35C
YYYY/MM/DD
Past Minimum Temp/Date
:
5C
YYYY/MM/DD
Runtime (Out Of Given Temp)
:
99999 h 00min
Number (Start And Stop)
:
9999999999 times
Total Operating Time
:
99999 h 00min
Remains Of User Area
:
about 12345 MB
Maker Name/Model Name
:
A
1
14
*
1
*
1
E
F
16
12
22
13
15
18
19
17
20
21
detailed
●
Description of operations
1 Title
12 Present
temperature
13 Serial
14 Past highest temperature
15 Past highest temperature (Date when hit the record)
16 Past minimum temperature
17 Past minimum temperature (Date when hit the record)
18 Period of time when it is outside of the exceeding the
assured temperature range
19 Number of start and stop operations
20 Total operating time (Accumulated operation period of
time)
21 Capacity of remaining user area
22 Maker name and Model name
A
Shift to “Engineering Diag Menu (Page2)” screen.
E
Scroll character to left.
F
Scroll character to right.
■
HF Voice Quality Parameter screen
∗
This screen is valid only in the Japan model.
Menu
SET
HF Voice Quality Parameter
All-Def
Default
1
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
INT_INTERVAL
F F F F F F F F
A
B
C
D
G
H
I
2
3
●
Description of operations
1 Title
2 Parameter
name
3 Parameter
value
A
Enter the value, 0~F.
B
Set the parameter value.
C Reset the parameter value to the initial (default) value.
D Reset all the parameter values to their initial (default)
value.
G Shift to “Engineering Diag Menu (Page2)” screen.
H Display the preceding parameter.
I
Display the succeeding parameter.
■
BT RF Test screen
Menu
Tx TEST
Rx TEST
DUT MODE
Reset
Bluetooth RF TEST MODE
1
0ch
DH1
Frequency
Tx TEST Parameter
Packet Type
A
F
G
H
I
J
K
L
M
2
3
4
5
TEST MODE