SAFETY INTERLOCK ACCESS CONTROL SYSTEM
5
INPUT FEATURES:
Safety Loop:
Door 1: Normally closed contacts
Door 2: Normally closed contacts
Auxiliary: Normally closed contacts
Emergency access: Normally closed contacts
Emergency stop: Normally closed contacts
• Voltage across inputs: 12VDC
• Current: 61mA nominal
• Inputs can be daisy chained together to offer multiple external options
Remote Start:
• Voltage across inputs: 12VDC
• Current: 61mA nominal
Exit Request:
• Voltage across inputs: 12VDC
• Current: 24mA nominal
OTHER COMPONENTS:
Chime:
• Rated voltage: 12VDC
• Current rating: 35mA
• Sound pressure: >80dB @ 12VDC (at 1 foot)
SYSTEM INSTALLATION
4-1.
Remove components from packaging and verify that all components have been received and are not
damaged.
4-2.
Mount components in a visible location, where labels can be read and controls can be operated easily.
4-3.
Create a template by either tracing each component outline on paper, or hold the product firmly against the
wall and mark the hole locations prior to mounting equipment.
4-4.
We recommend mounting the lowest point of the control panel between 48-56 inches above finished floor.
4-5.
External wiring should be located within conduit or within the wall.
4-6.
A basic wiring layout diagram is included with this manual (Section 10-1). Custom wiring drawings can be
provided on request. All components should be wired by a certified electrician.
4-7.
Please call 1-800-432-2323 if you have any questions about the installation of this product.
The following installation checklist is only a guide and is intended to be used by qualified service technicians. The
sequence of the checks is arbitrary. Actual sequence will be determined by the technician performing the checks.
General System Information
The system is considered engaged when all of the following conditions are met:
4-8.
‘START’ LED is illuminated.
4-9.
‘MAGLOCK ON’ LED is illuminated.
4-10. All doors to the protected room are locked (if equipped with magnetic or electronic locks).
4
.
Summary of Contents for Entry-Guard
Page 1: ...OPERATION MANUAL SAFETY INTERLOCK ACCESS CONTROL SYSTEM...
Page 11: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 11 Section 10 1 APPLICATION LAYOUT OPTIONS...
Page 12: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 12 Section 10 2 CONTROL PANEL FACEPLATE...
Page 13: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 13 Section 10 3 PRINTED CIRCUIT BOARD PCB EG001...
Page 14: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 14 Section 10 4 PRINTED CIRCUIT BOARD PCB EG001 LAYOUT...
Page 15: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 15 Section 10 5 PRINTED CIRCUIT BOARD PCB EG MPI...
Page 16: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 16 Section 10 6 PRINTED CIRCUIT BOARD PCB EG MPI LAYOUT...
Page 17: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 17 Section 10 7 REMOTE START WIRING...
Page 18: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 18 Section 10 8 ACCESS CONTROL WIRING...
Page 19: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 19 Section 10 9 EMERGENCY ACCESS WIRING...
Page 20: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 20 Section 10 10 EMERGENCY STOP WIRING...
Page 21: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 21 Section 10 11 DOOR INTERLOCK WIRING...
Page 22: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 22 Section 10 12 KEYPAD WIRING...
Page 23: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 23 Section 10 13 MAGNETIC LOCK WIRING...
Page 24: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 24 Section 10 14 SINGLE STATUS SIGN WIRING...
Page 25: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 25 Section 10 15 DUAL STATUS SIGN WIRING...
Page 26: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 26 Section 10 16 TRIPLE STATUS SIGN WIRING...
Page 27: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 27 Section 10 17 PCB SIGN WIRING...
Page 28: ...SAFETY INTERLOCK ACCESS CONTROL SYSTEM 28 Section 10 18 BYPASS KEY SWITCH WIRING...