Part 6: Replacing the UF Membrane
+
Part 7: Restoring your KENT Gold
(when leaving for long vacations)
+
Gold Installation Manual 11
10 KENT RO SYSTEMS LTD.
Frequency:
Purifier should be restored, when going on a vacation for more than 7 days.
Remove the Inner Tank
Remove the Top Lid by pressing it
down and rotating anti-clockwise.
Remove the Filter Assembly
Remove the Top Cover from the
Inner & Outer Tank Assembly
With the help of Y-FORK, press
the collet down and pull up the
Membrane Cartridge
Take off the Inner Tank from
the partition
Unscrew the tap of the
Inner Tank
Wipe dry all the plastic parts
inside-out with a clean cloth.
Re-assemble the dry purifier
1
2
3
4
5
6
7
8
9
Frequency:
UF Membrane should be changed every year.
Press it
down in
collet
Collet
Pull up
with
one hand
Press down
with the other hand
UF Membrane
Remove the Inner Tank
Place it upside down
Press the Collet down with the help of Y- Fork. With the Collet pressed down,
pull up the Membrane Cartridge.
Take 50 ml of pure water in the syringe and inject
it into the Membrane Cartridge (opposite to the
direction of flow) to soak the new Membrane
Press down the new Membrane Cartridge
and fix it to the Inner Tank.
Note:-Be careful to insert it opposite to the
direction of water flow.
1
2
3
4
5
Remove the Membrane Cartridge
Y- Fork