KENT Gold+ User Manual Download Page 4

2  KENT RO SYSTEMS LTD.

+

Gold  Installation Manual  3

Tap

SS Screen

Ideal for Tap water or Municipal Corporation water supply

Use of Hollow Fiber Ultra Filtration (UF) Membrane filters 

as well as reduces 

. Cysts are deadly pathogens that cannot be removed  by  most  non-electric  storage  

water  purifiers

No use of chemicals such as Chlorine, Bromine or Iodine for purification, thereby  providing healthier and tastier drinking  water

Use of Activated Carbon Filter for better contaminant reduction of water

Designed with a high Bottom Stand so that a glass can be filled easily and the purifier is not required to be placed at the 

edge of a table/slab

High storage capacity of 20 litres, to provide purified water on demand

Food grade plastic construction for trouble-free maintenance and a long life

bacteria (certified by Toray, Japan) 

cysts 

(certified by NSF International)

Salient  Features

Technical  Specifications

+

Know  your  KENT  Gold

Manufacturer  Details

: KENT  RO  SYSTEMS  LTD.

A-2, Sector-59, Noida, U.P.- 201 309, India Ph.: +91-120-3075075
[email protected]

+

Model

: KENT  Gold   UF  Membrane  Storage Water  Purifier

Model  No. 

: 11015

Mounting

: Table  top

Dimensions

: H  (540mm), W  (360mm),  D  (380mm)-  (when  assembled)

Inner Tank  storage  capacity : 10  litres  (Approx.)

Outer Tank  storage  capacity : 10  litres   (Approx.)

Membrane  type

: UF  Membrane

Filters

: Sediment,  Granuler  Activated  Carbon,  SS(Stainless  Steel)  Screen

Expected life of UF Membrane : 4000  litres  /  1058  gallons

Maximum  Operating 
Water Temperature

: 35°C/

Minimum  Operating 
Water Temperature

:

Filtration Capacity

: 0.31 litre per minute (under standard testing conditions)

Usage

: The system should be used only with cold water.

95°F

10°C/50°F

WQA Performance Data: 

This system has been tested according to S-200 for reduction of the substances listed below. 

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or 

equal to the permissible limit for water leaving the system, as specified in S-200."

Substances

Minimum 
Percent 

Percent

Challenge

Permissible

Influent 

Effluent

Reduction

Reduction 

Concentration 

product water

Concentration

Concentration 

(mg/L)

 concentration 

(mg/L)

(mg/L)

(mg/L)

 

Alachlor

85%

87%

0.04 + 10%

0.002

0.04

0.001

Average

Influent 

Maximum 

Average

Average  

NSF Performance Data

This system has been tested under NSF/ANSI 53 for reduction of the substances listed below. The concentration of the 

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible 

limit for water leaving the system as specified in NSF/ANSI 53.

Substance

Influent challenge concentration

Reduction requirement

cyst

minimum 50,000/L

99.95%

Percentage of Cyst
Reduction after testing 99.99% reduction
(Though testing was performed under standard laboratory conditions actual performance may vary.)

"Gold filters are certified by WQA to S-200 for the reduction of chlorine, taste and odour only, as verified and 
substantiated by test data."

Top Lid

Top Cover

Inlet Funnel

Sediment Filter

Inner Tank

UF Membrane Cartridge

Bottom Stand

Granuler Activated Carbon Filter

Outer Tank

Fitting

Summary of Contents for Gold+

Page 1: ...nufactured by Khasra No 93 Village Bantakhedi Tehsil Roorkee District Haridwar Uttarakhand 247 668 India KENT RO SYSTEMS LTD Instruction Handbook for Installation Operation and Maintenance System Test...

Page 2: ...or any sickness or illness due to the consumption of drinking water from any water purifier supplied by KENT since KENT or its Authorised Service Provider does not have any control over the maintenanc...

Page 3: ...xploded view of KENT Gold 4 7 Important instructions 5 8 Filtration process 5 9 Setting up your KENT Gold 6 10 Maintaining your KENT Gold 7 Part 1 Cleaning the UF Membrane 7 Part 2 Cleaning the water...

Page 4: ...Operating Water Temperature 35 C Minimum Operating Water Temperature Filtration Capacity 0 31 litre per minute under standard testing conditions Usage The system should be used only with cold water 9...

Page 5: ...ding on the quality of raw water 6 Replace the Sediment Filter every 3 months 7 Replace the Activated Carbon Filter every 6 months 1800 litres 8 Replace the UF Membrane every 12 months 9 At the time o...

Page 6: ...STEMS LTD Gold Installation Manual 7 Fequency l The UF Membrane should be cleaned at least once in a month However if the water flowing from InnerTank to the Outer Tank reduces sharply Membrane can be...

Page 7: ...lean both the Filters Pressure clean the Funnel under running tap water Part 2 Cleaning the Water Tanks 8 KENT RO SYSTEMS LTD 1 2 3 4 5 6 1 2 3 4 Frequency The Sediment Filter should be changed after...

Page 8: ...f the Inner Tank Wipe dry all the plastic parts inside out with a clean cloth Re assemble the dry purifier 1 2 3 4 5 6 7 8 9 Frequency UF Membrane should be changed every year Press it down in collet...

Page 9: ...fy dsUV k mlds vf k r lfoZl dsUnz dks ft Eesnkj ugha Bgjk k tk ldrk D ksafd dsUV k mlds vf k r lfoZl dsUnz dk okWVj I qfjQk j ds j kj kko vkSj bLrseky ij dksbZ fu a k ugha gSA 12 okjaVh vuqca k esa mR...

Page 10: ...V xksYM dk foLr r n 4 7 egRoiw kZ funsZ k 5 8 fQYV s ku izf k 5 9 dsUV xksYM dk baLVkWys ku 6 10 dsUV xksYM dk j k j kko 7 Hkkx 1 w Q esEczsu dh lQkbZ 7 Hkkx 2 ikuh dh Vafd ksa dh lQkbZ 8 Hkkx 3 lsMhe...

Page 11: ...Vj 1058 xSyu vf kdre vki W jf s Vx a ikuh dk rkieku 35 U wure vkWijsfVax ikuh dk rkieku 10 fQYV s ku kerk 0 31 yhVj izfr feuV LVSUMMZ VsfLVax ifjfLFkfr ksa ds rgr bLrseky BaMs ikuh ds fy C 95 F C 50 F...

Page 12: ...062 fooj k dsUV xksYM Lis j fdV 20065 esEczsu dsUV xksYM 1 20063 fDVosfVM dkcZu 190xzke 1 20064 lsMhesaV fQYVj dsUV xksYM tksM h 14 bl flLVe ls igys k ckn esa fcuk fdlh ksX fMflaQsD ku ds vlqjf kr k v...

Page 13: ...dks j ksaA Vd as lc as yh ij ijh Ddu yxk A as Ddu dks dl dj can djus ds fy mls kM h dh fn kk esa kqek saA vkidk I qfjQk j bLrseky ds fy rS kj gSA 1 2 3 10 12 5 6 4 8 9 7 11 l bart kj djsa l baLVkWys k...

Page 14: ...d ckj vo lkQ djsaA mls mYVk dj ds j ksaA Ik kZIr ikuh Mkydj lsMhesaV oa dkcZu fQYVj dks vPNs ls kks aA fQYVj lsEcyh dks uy ds uhps rst kkj ls lkQ djsaA fQYVj gkmflx a dks kky s rs g q Quy ls vyx djA a...

Page 15: ...j ikuh ysdj mls esEczsu esa batsDV djsaA vc u h esEczsu dks uhps dh vksj nckrs gq Hkhrjh Vadh esa fQV djsaA esEczsu dks ikuh dh fn kk ds foijhr Hkhrj Mkyrs le lko kkuh cjrsaA bls dkWysV esa uhps dh vk...

Reviews: