VACUUM MOTOR
REPLACEMENT
AquaPro
TM
300
(120V & 240V)
BEFORE BEGINNING REPAIRS: Unplug the machine, empty all water from the tanks, open
the latches and prop the tanks up.
VACUUM MOTOR REMOVAL:
1. Check to be sure the machine is unplugged.
2.
Cut the ground wires (green/yellow) from the vac motor, about 3 inches from the insulated
butt connector. See Figure 1 below. Leave enough wire for re-connection.
3.
Cut and remove the small tie wraps that secure the wiring together. See Figure 1.
4.
Locate and cut the 2 power wires from the vac motor, a few inches from the motor. See
figure 1 below. Note the correct location of wires. Leave enough wire for reconnection.
Leave the power wires connected to the vacuum control circuit board (if applicable).
STEP 4:
Cut the 2 power cords
from the vac motor a few inches
from the motor.
STEP 3:
Cut and remove
small tie wraps
FIGURE 1
STEP 2:
Cut the
ground wire(s)
about 3 inches
from insulated
butt connector
(not shown).
FIGURE 1