17
The lower thermostat is factory set at a position which
approximates 120°F (49°C), and is adjustable if a different water
temperature is desired. Read all warnings in this manual and
on the water heating before proceeding.
FIGURE 27.
Temperature Settings
Time to Produce
Temperature
2nd & 3rd Degree
Setting
Burns on Adult Skin
160°F (71°C)
About 1/2 second
150°F (66°C)
About 1-1/2 seconds
140°F (60°C)
Less than 5 seconds
130°F (54°C)
About 30 seconds
120°F (49°C)
More than 5 minutes
NOTE: Water temperature range of 120°—140°F (49°-60°C)
recommended by most dishwasher manufacturers.
Upper and Lower Thermostat Adjustments
(Refer to thermostat illustrations under
“Thermostat”
section)
Temperature Regulation
HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. Water heated to a temperature which will satisfy
clothes washing, dish washing, and other sanitizing needs can
scald and permanently injure you upon contact. Some people
are more likely to be permanently injured by hot water than others.
These include the elderly, children, the infirm, or physically/
mentally handicapped. If anyone using hot water in your home
fits into one of these groups or if there is a local code or state law
requiring a certain temperature water at the hot water tap, then
you must take special precautions. In addition to using the lowest
possible temperature setting that satisfies your hot water needs,
some type of tempering device, such as a mixing valve, should
be used at the hot water taps used by these people or at the
water heater. Mixing valves are available at plumbing supply or
hardware stores. Follow manufacturers instructions for installation
of the valves, Before changing the factory setting of the thermostat
see Temperature Settings table at right.
Never allow small children to use a hot water tap, or to draw
their own bath water. Never leave a child or handicapped person
unattended in a bathtub or shower.
Thermostats
The thermostats of this water heater have been factory set at a
position which approximates 120°F (49°C), to reduce the risk
of scald injury.
The upper thermostat is factory set at a position which
approximates 120°F (49°C) and is adjustable if a different water
temperature is desired. Read all warnings in this manual and
on the water heating before proceeding.