- 3 -
1. SPECIFICATIONS
1-1 DISCONNECT POWER CORD BEFORE
SERVICING
IMPORTANT - RECONNECT ALL
GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts or washers used to complete a path to ground
are removed for service, they must be returned to their
original position and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical, electronic
and mechanical experience. Any attempt to repair a major
appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
1-7 REPLACEMENT PARTS
Defrost Thermostat ....................................... 6615JB2005H
Defrost Heater ............................................... 5300JK1005D
Evaporator Fan Motor ................................... 4681JB1027C
Capacitor (Running) ..................................... EAE58905701
Compressor (Hi-Side) ................................... TCA34649901
Evaporator (Lo-Side) ...................................... 5421JJ1003L
Condenser ................................................... ACG72915205
Dryer ............................................................. 5851JA2007E
Condenser Fan Motor .................................. .4681JB1029D
Temperature Control .......................... ABQ56655314(STS)
ABQ56655316(WB)
ABQ56655315(SW)
Main Control ................................................. EBR67348004
Refrigerator Fan Motor ....................................4681JB1027J
28cu,ft
795.71042.01*
795.71043.01*
795.71049.01*
1-8 AIR FLOW / CIRCULATION D’AIR
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (Freezer Compartment) . -6°F to +8°F
Defrost Control ......Total Comp Running Time: 7 hrs~50 hrs
Defrost Thermostat ...................................................... 46°F
Electrical Rating : 115VAC, 60Hz ................................ 4.2 A
Maximum Current Leakage ...................................... 0.5 mA
Maximum Ground Path Resistance ................... 0.14 Ohms
Energy Consumption ........................ 28cu,ft. 489 (E/STAR)
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ................ 21 MIN.
Minimum Equalized Pressure
@ 70°F ............................................................ 49 PSIG
@ 90°F ............................................................ 56 PSIG
Refrigerant R134a ................................................... 4.59 oz.
Compressor ....................................................... 956 BTU/hr
1-6 INSTALLATION
Clearance must be provided at rear of the refrigerator for air
circulation.
AT REAR ........................................................................ 2 in
1-4 NO LOAD PERFORMANCE
CONTROL POSITION: MID/MID
And Ambient of : ................ 70°F ................................. 90°F
Fresh Food, °F .................. 33°F to 41°F ........ 33°F to 41°F
Frozen Food, °F ................ -4°F to +4°F ......... -4°F to +4°F
Percent Running Time ...... 35%-45% ................. 50°F-70°F
Summary of Contents for 795.71042.01
Page 14: ... 14 5 CIRCUIT DIAGRAM ...
Page 16: ... 16 6 2 Display PCB Sub PCB P No Display PCB EBR42479303 2010 03 Picture CON01 ...
Page 59: ...616E 623B 619A 627B 623A 600A 600B 1 ICEMAKER PARTS ...
Page 61: ... 3 CASE PARTS ...
Page 62: ... 4 CASE PARTS ...
Page 66: ... 8 DOOR PARTS ...