- 20 -
0
Ω
OFF
Other
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-3)
Result
SVC Action
7-4 Defrost Sensor Error (F dS)
No
1
2
Checking flow
Check for a loose connection.
Check the Orange to Orange.
Result & SVC Action
Check the Brown to Brown.
※
The sensor is determined by
the temperature.
For example, 23
㏀
indicates -4°F.
<CON4>
<Temperature table-3>
(1) To (2)
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38.5 ~ 36.5
㏀
30.5 ~ 29.5
㏀
24.5 ~ 23.5
㏀
20 ~ 19
㏀
16 ~15.5
㏀
Summary of Contents for 795.71042.01
Page 14: ... 14 5 CIRCUIT DIAGRAM ...
Page 16: ... 16 6 2 Display PCB Sub PCB P No Display PCB EBR42479303 2010 03 Picture CON01 ...
Page 59: ...616E 623B 619A 627B 623A 600A 600B 1 ICEMAKER PARTS ...
Page 61: ... 3 CASE PARTS ...
Page 62: ... 4 CASE PARTS ...
Page 66: ... 8 DOOR PARTS ...