7-3 Icing Sensor Error (Er IS)
0
Ω
OFF
Other
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-1)
Result
SVC Action
No
1
2
Checking flow
Check for a loose connection.
Check the Red to Bright Orange.
Result & SVC Action
<Temperature table-1>
(1) To (2)
-22°F / -30°C
-13°F / -25°C
-4°F / -20°C
5°F / -15°C
14°F / -10°C
23°F / -5°C
32°F / 0°C
Result
40.5 ~ 38.5
㏀
30.5 ~ 28.5
㏀
23 ~ 21.5
㏀
17.5 ~ 16.5
㏀
13.5 ~ 12.5
㏀
10.5 ~ 9.5
㏀
8 ~7.5
㏀
※
The sensor is determined by
the temperature.
For example, 23
㏀
indicates -4°F.