![Kendrion Econo 206 User Manual Download Page 36](http://html1.mh-extra.com/html/kendrion/econo-206/econo-206_user-manual_663785036.webp)
Kendrion Kuhnke Automation GmbH
Construction and Functionality
Econo
36
4.7 Indicators and Controls, Econo
4.7.1 Status LEDs
The status LEDs indicate the state of the panel PC's modules. RUN / STOP is reserved for indicating the
status of the soft PLC, if any.
Indicators:
LED
Description
Designation
LED
Explanation
Power
off
No 24 VDC power supply
blue
24 VDC power supplied
Run/Stop
off
yellow
Device is booting
green
PLC status is "run"
red
PLC status is "stop"
CAN1
off
no CAN communication
flashing yellow
CAN communicating
CAN2
off
no CAN communication
flashing yellow
CAN communicating
4.7.2 Ethernet "LAN1" (X2), "LAN2" (X3)
LED
Both LAN1 and LAN2
Designation
LED
Explanation
1
off
10 Mbps
green
100 Mbps
orange
1000 Mbps
2
off
orange
connected
flashing orange
activity
LAN1
X2
LAN2 / ECAT
X3