SuperSnake GTX
Operating manual - EN
2.
Wire feed roll (drive roll)
3.
Wire feed roll (pressure roll)
4.
Wire outlet guide tube
5.
Wire inlet guide tip
6.
Subfeeder control panel
>> Displays for wire feed speed / welding current and for fine tuning
>> Error indicator (red), warning indicator (yellow)
7.
Control knobs
>> A: Wire feed speed and/or welding current
>> B: Fine tuning (e.g. voltage, depending on welding process)
Automatic control knob activation: When the control knobs are not used, they are automatically deactivated to pre-
vent accidental changing of welding parameters. The control knob functions are activated again by turning either of
the control knobs a quarter of a turn. When active, the LED indicator between the control knobs turns green.
8.
Wire inch and Gas test buttons
9.
Welding ON/OFF indicator (lock)
>> Lock symbol is lit if the welding is turned off from the switch (10)
10.
Welding ON/OFF switch
>> Prevents welding with the subfeeder if set to OFF.
The welding ON/OFF switch doesn't power down the subfeeder.
Subfeeder front connections
1.
Welding cable Euro connector (for welding gun)
2.
Control cable connector (e.g. for remote control)
© Kemppi
5