 Kelvinator Gas Continuous Flow hot water system

Congratulations and thank you for choosing our gas 
continuous flow hot water system. We are sure you will find  
your new hot water system a pleasure to use. Before you 
install the hot water system, we recommend that you read 
through the entire installation manual, which provides the 
description of the hot water system, its functions and how to 
install it correctly. To avoid the risks that are always present 
when you use an appliance, it is important that the hot water 
system is installed correctly and that you read the safety 
instructions carefully to avoid misuse and hazards.
After unpacking the hot water system please check it is not 
damaged. If in doubt, do not use the hot water system but  
contact your local Electrolux Customer Care Centre using the 
number located at the back of this installation guide.

NOTE: The actual gas heating appliance that is part of this 
gas continuous flow hot water system will here after be 
refered to as "water heater" for the purposes of this manual. 
The gas continuous flow hot water system as a whole may 
also be refered to as "hot water system" for simplicity.

environmental tips

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 
recycling depot or by placing them in appropriate 
collection containers.

•    If you wish to discard this gas continuous hot water 

system, please contact your local authorities and ask for 
the correct method of disposal.

caution

•    The hot water system is not intended for use by young 

children or infirm persons without supervision.

•   Children should be supervised to ensure that they do  
 

not play with the hot water system. 

•    Contact an authorised installer for installation of this hot 

water system.

•    Contact an authorised service technician for repair or 

maintenance of this hot water system.

•    If the power cord is to be replaced, replacement work  

must be performed by authorised personnel only.

•    Installation work must be performed in accordance  

with national standards by authorised personnel only. 
Wrong connection can cause over heating or fire.

•   This hot water system should be installed in accordance 

with AS/NZS 3000 and your electricity suppliers rules.

•  The installation of this hot water system must comply 

with the standards set in AS/NZS 3500.4 - Hot Water 
Supply Systems.

Conditions of use

This hot water system is intended to be used in household 
and similar applications such as :
•  staff kitchen areas in shops, offices and other working  
 environments.
•  farm houses.
•  by clients in hotels, motels and other residential type  
 environments.
•  bed and breakfast type environments

Important .......................................................................... 3
Important safety instructions ........................................... 4
For the plumber ................................................................ 5
Dimensions and connection points ................................... 6 
Installation ......................................................................... 8
Clearances ......................................................................... 9
Gas connection ................................................................ 10
Water connection ............................................................ 11 
Electrical connection ....................................................... 12 
Remote controller ..........................................................  13
Remote controller Installation ........................................ 14
Commissioning Instructions ............................................ 16
Troubleshooting .............................................................. 18
PCB error codes .............................................................. 19
Warranty .......................................................................... 23 

Congratulations

Contents

Summary of Contents for KGC20BNA

Page 1: ...Gas Continuous Flow Hot Water System Installation Manual...

Page 2: ...s gas continuous hot water system please contact your local authorities and ask for the correct method of disposal caution The hot water system is not intended for use by young children or infirm pers...

Page 3: ...n concerning use by a person responsible for their safety Children should be supervised to ensure that they do not play with the gas continuous flow hot water system This symbol indicates never to do...

Page 4: ...y or loss of life 1 The gas continuous flow hot water system does not have a pilot It is equipped with an internal ignition device that automatically lights the burner Do not try and light the burner...

Page 5: ...GC26KNA KGC26SNA KGC26BLA KGC26KLA KGC26SLA Capacity L min 20L min 26L min Gas Input MJ h 160 195 Supply Inlet Pressure kPa Nat Gas 1 13 min 1 13 min 2 75 max 2 75 max Supply Inlet Pressure kPa LPG 2...

Page 6: ...A KGC20KLA KGC20SNA KGC20SLA 124mm 490mm 520mm 31mm power 47mm gas 133mm 94mm 60mm 198mm 350mm top fixing positions top fixing positions 330mm hot 98mm 70mm 108mm 30mm cold gas 335mm 19mm 37mm 49mm co...

Page 7: ...Exterior view KGC26BNA KGC26BLA KGC26KNA KGC26KLA KGC26SNA KGC26SLA power cold 84mm 34mm gas 124mm 133mm hot 41mm hot 49mm cold 490mm 520mm 25mm power 44 5mm gas 350mm 37mm 19mm 198mm 330mm 94mm 60mm...

Page 8: ...and 70 C models The water heater requires a fireproof back plate if installed on timber wall Selecting an installation location Carefully read this section before selecting the installation location a...

Page 9: ...ll fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1000 n Vertically below an openable window non mechanical air outlet or any othe...

Page 10: ...onnect any water lines to the gas inlet It may be critically damaged power cord gas inlet supply gas valve Sizing and connection Check the gas type label to make sure that the water heater was built f...

Page 11: ...systems A manual shut off valve must be installed on the cold water inlet to the water heater between the main water supply line and the water heater Only a gate valve or a ball valve is to be used on...

Page 12: ...rules 5 The insulation of the fixed wiring must be protected by insulating sleeving having an appropriate temperature rating 6 If the supply cord is to be replaced this must be done by a service techn...

Page 13: ...n or water heater the remote controller will display a numerical error code Main remote controller model KGCMRCA KGCMRCA must be installed inside as it is NOT water resistant Allows the output tempera...

Page 14: ...to attach the remote control to gyprock you should use the anchor plug use the fork terminals 25mm remote control wiring connector base 83 5mm 45mm warning The remote controller must be installed insi...

Page 15: ...onnect remote control wires to remote terminals directly There is no polarity in the terminations plastic cover KGCMRCA typical cable layout remote control terminal remote control cable Remove the pla...

Page 16: ...inlet to the water heater 7 Check the gas pipe work for leaks and stop the leaks as necessary caution If there is a gas leak that cannot be stopped do not try to start the water heater Do not touch a...

Page 17: ...n to be handed to the customer or left in a suitable location on the premises If the customer is available they are to be instructed on the safe and correct operating of the water heater and any auxil...

Page 18: ...o keep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature Is...

Page 19: ...he bottom left hand side of the cabinet and the error codes can be read from the LED on the PCB Error Codes on the PCB The LED on the PCB Symptom LED light blinks once Incorrect dipswitch setting gas...

Page 20: ...20 notes Kelvinator Gas Continuous Flow hot water system Notes...

Page 21: ...Kelvinator Gas Continuous Flow hot water system notes 21 Notes...

Page 22: ...22 notes Kelvinator Gas Continuous Flow hot water system Notes...

Page 23: ...is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a clai...

Page 24: ...er information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux c...

Reviews: