background image

13. If a remote controller has been installed, check that the 

controller operates correctly (refer page 13 of  
this manual).

PRIORITY

°C

BURNER ON

PRIORITY

°C

BURNER ON

ON/OFF

PRIORITY

HOT

COOL

MADE IN JAPAN

Main

ON/OFF

PRIORITY

HOT

COOL

MADE IN JAPAN

Shower

PRIORITY

°C

BURNER ON

ON/OFF

PRIORITY

HOT

COOL

MADE IN JAPAN

Ensuite

The gas continuous flow hot water system should now be 
operating correctly.

Now that commissioning has been completed and the gas 
continuous flow hot water system has been set up to operate 
correctly, select the correct model number of the water 
heater on page 5 of the user manual. Fill out your details, the 
serial number, installation date and include any important 
notes to the customer. The user manual is then to be handed 
to the customer or left in a suitable location on the premises. 
If the customer is available they are to be instructed on 
the safe and correct operating of the water heater and any 
auxiliary equipment.

 If the hot water system isn’t going to be used for a long time 
and needs to be turned off after commissioning, follow these 
instructions:

•  Switch off the electrical supply at the power outlet that 

the water heater is plugged into

•  Close the gas isolation valve located on the inlet to the 

water heater

•  Close the cold water isolation valve located on the inlet to 

the water heater

Note: If there is a risk of freezing conditions, do not switch off 
power to the water heater unless it is drained of water first. 
Please see the section on freeze prevention on page 9 of the 
user manual for more information.

Commissioning instructions 

(continued)

 Kelvinator Gas Continuous Flow hot water system 

 commissioning instructions  17 

Summary of Contents for KGC20BNA

Page 1: ...Gas Continuous Flow Hot Water System Installation Manual...

Page 2: ...s gas continuous hot water system please contact your local authorities and ask for the correct method of disposal caution The hot water system is not intended for use by young children or infirm pers...

Page 3: ...n concerning use by a person responsible for their safety Children should be supervised to ensure that they do not play with the gas continuous flow hot water system This symbol indicates never to do...

Page 4: ...y or loss of life 1 The gas continuous flow hot water system does not have a pilot It is equipped with an internal ignition device that automatically lights the burner Do not try and light the burner...

Page 5: ...GC26KNA KGC26SNA KGC26BLA KGC26KLA KGC26SLA Capacity L min 20L min 26L min Gas Input MJ h 160 195 Supply Inlet Pressure kPa Nat Gas 1 13 min 1 13 min 2 75 max 2 75 max Supply Inlet Pressure kPa LPG 2...

Page 6: ...A KGC20KLA KGC20SNA KGC20SLA 124mm 490mm 520mm 31mm power 47mm gas 133mm 94mm 60mm 198mm 350mm top fixing positions top fixing positions 330mm hot 98mm 70mm 108mm 30mm cold gas 335mm 19mm 37mm 49mm co...

Page 7: ...Exterior view KGC26BNA KGC26BLA KGC26KNA KGC26KLA KGC26SNA KGC26SLA power cold 84mm 34mm gas 124mm 133mm hot 41mm hot 49mm cold 490mm 520mm 25mm power 44 5mm gas 350mm 37mm 19mm 198mm 330mm 94mm 60mm...

Page 8: ...and 70 C models The water heater requires a fireproof back plate if installed on timber wall Selecting an installation location Carefully read this section before selecting the installation location a...

Page 9: ...ll fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1000 n Vertically below an openable window non mechanical air outlet or any othe...

Page 10: ...onnect any water lines to the gas inlet It may be critically damaged power cord gas inlet supply gas valve Sizing and connection Check the gas type label to make sure that the water heater was built f...

Page 11: ...systems A manual shut off valve must be installed on the cold water inlet to the water heater between the main water supply line and the water heater Only a gate valve or a ball valve is to be used on...

Page 12: ...rules 5 The insulation of the fixed wiring must be protected by insulating sleeving having an appropriate temperature rating 6 If the supply cord is to be replaced this must be done by a service techn...

Page 13: ...n or water heater the remote controller will display a numerical error code Main remote controller model KGCMRCA KGCMRCA must be installed inside as it is NOT water resistant Allows the output tempera...

Page 14: ...to attach the remote control to gyprock you should use the anchor plug use the fork terminals 25mm remote control wiring connector base 83 5mm 45mm warning The remote controller must be installed insi...

Page 15: ...onnect remote control wires to remote terminals directly There is no polarity in the terminations plastic cover KGCMRCA typical cable layout remote control terminal remote control cable Remove the pla...

Page 16: ...inlet to the water heater 7 Check the gas pipe work for leaks and stop the leaks as necessary caution If there is a gas leak that cannot be stopped do not try to start the water heater Do not touch a...

Page 17: ...n to be handed to the customer or left in a suitable location on the premises If the customer is available they are to be instructed on the safe and correct operating of the water heater and any auxil...

Page 18: ...o keep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature Is...

Page 19: ...he bottom left hand side of the cabinet and the error codes can be read from the LED on the PCB Error Codes on the PCB The LED on the PCB Symptom LED light blinks once Incorrect dipswitch setting gas...

Page 20: ...20 notes Kelvinator Gas Continuous Flow hot water system Notes...

Page 21: ...Kelvinator Gas Continuous Flow hot water system notes 21 Notes...

Page 22: ...22 notes Kelvinator Gas Continuous Flow hot water system Notes...

Page 23: ...is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a clai...

Page 24: ...er information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux c...

Reviews: