These steps are to be followed after the installation of the 
gas continuous flow hot water system to ensure its safety 
and performance. If the hot water system cannot be setup to 
perform correctly as specified in this manual, please call the 
service centre (number located in the warranty section of this 
manual) for further instructions. 

 

      

      

      

      

 

 

 

gate or ball 

valve on inlet

drain plug

filter

1.  Remove and clean the filter located on the cold water 

inlet to the water heater (refer to page 11 of this manual).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      

      

      

      

 

 

 

2.  Open all the hot taps and fixtures in the house.
 

 

 

 

 

3.  Open the cold water isolation valve fully at the inlet to the 

water heater

4.  Check all pipe work for leaks and stop the leaks as 

necessary

5.  Once all the air has been forced out of the system and 

water is flowing freely from every hot tap or fixture, close 
all hot taps and fixtures

6.  Open the gas isolation valve fully by hand at the inlet to 

the water heater

 

 

 

 

 

 

 

 

 

 

 

 

7.  Check the gas pipe work for leaks and stop the leaks as 

necessary 

caution

If there is a gas leak that cannot be stopped, do not try to 
start the water heater. Do not touch any electrical switches, 
use a mobile phone or any other ignition source. Close the 
main gas isolating valve to the premises and walk a safe 
distance away. Call the gas supplier and follow the gas 
supplier’s instructions.

8.  Check the inlet gas pressure (refer page 10 of this 

manual).

9.  Plug the power cord into the socket outlet and switch on 

the electrical supply.

 

10. Open a hot water tap or fixture.
 

•  If there is sufficient water flow the water heater  
  should start up automatically

11.  Check each hot water tap or fixture to ensure that there 

is sufficient flow to operate the water heater (minimum 3 
litres per minute).

12. Check the temperature of the hot water at each hot tap or 

fixture intended primarily for personal hygiene to ensure 
the temperature is not higher than 50°C.

Commissioning instructions

16  commissioning instructions 

 Kelvinator Gas Continuous Flow hot water system

filter

Summary of Contents for KGC20BLA

Page 1: ...Gas Continuous Flow Hot Water System Installation Manual ...

Page 2: ...is gas continuous hot water system please contact your local authorities and ask for the correct method of disposal caution The hot water system is not intended for use by young children or infirm persons without supervision Children should be supervised to ensure that they do not play with the hot water system Contact an authorised installer for installation of this hot water system Contact an au...

Page 3: ...on concerning use by a person responsible for their safety Children should be supervised to ensure that they do not play with the gas continuous flow hot water system This symbol indicates never to do this This symbol indicates always do this warning Connect with power properly Otherwise it may cause electric shock or fire due to excess heat generation Always ensure effective earthing No earthing ...

Page 4: ...ry or loss of life 1 The gas continuous flow hot water system does not have a pilot It is equipped with an internal ignition device that automatically lights the burner Do not try and light the burner by hand 2 BEFORE OPERATING use a suitable gas detector to check all around the hot water system for evidence of leaking gas Be sure to check close to the ground if you are using LP gas as it is heavi...

Page 5: ...KGC26KNA KGC26SNA KGC26BLA KGC26KLA KGC26SLA Capacity L min 20L min 26L min Gas Input MJ h 160 195 Supply Inlet Pressure kPa Nat Gas 1 13 min 1 13 min 2 75 max 2 75 max Supply Inlet Pressure kPa LPG 2 61 min 2 61 min 2 89 max 2 89 max Water Supply Pressure kPa 150 min 150 min 1200 max 1200 max Height mm 542 542 Depth mm 170 215 Width mm 350 350 Weight kg 15 7 17 2 Gas Connection mm 20 BSP 20 BSP W...

Page 6: ...NA KGC20KLA KGC20SNA KGC20SLA 124mm 490mm 520mm 31mm power 47mm gas 133mm 94mm 60mm 198mm 350mm top fixing positions top fixing positions 330mm hot 98mm 70mm 108mm 30mm cold gas 335mm 19mm 37mm 49mm cold 41mm hot hot cold 79mm power 34mm gas 170mm 137mm 542mm 15 7mm 46mm cold 86mm gas 114mm hot 124mm power bottom fixing positions bottom fixing positions ...

Page 7: ... Exterior view KGC26BNA KGC26BLA KGC26KNA KGC26KLA KGC26SNA KGC26SLA power cold 84mm 34mm gas 124mm 133mm hot 41mm hot 49mm cold 490mm 520mm 25mm power 44 5mm gas 350mm 37mm 19mm 198mm 330mm 94mm 60mm 542mm 215mm 182mm 15 7mm 61mm cold 125mm gas 154mm hot 169mm power 109mm 153mm gas hot 138mm 335mm 45mm cold bottom fixing positions bottom fixing positions ...

Page 8: ... and 70 C models The water heater requires a fireproof back plate if installed on timber wall Selecting an installation location Carefully read this section before selecting the installation location and installing the water heater The installer must follow these precautions exactly caution Although the water heater is designed to operate with minimal noise it is recommended that you do not instal...

Page 9: ...All fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1000 n Vertically below an openable window non mechanical air outlet or any other opening into a building with the exception of sub floor ventilation Space heaters up to 50 MJ h input 150 Other appliances up to 150 MJ h input 500 Appliances over 50 MJ h input up to 150 MJ h inpu...

Page 10: ...connect any water lines to the gas inlet It may be critically damaged power cord gas inlet supply gas valve Sizing and connection Check the gas type label to make sure that the water heater was built for the type of gas you will be using and that the gas inlet pressure is within the appropriate range Please refer to page 5 1 Gas pressure below this specified range for the water heater and or insuf...

Page 11: ... systems A manual shut off valve must be installed on the cold water inlet to the water heater between the main water supply line and the water heater Only a gate valve or a ball valve is to be used on the cold water supply No stop taps or check valves are to be used as this will void the warranty and damage the water heater Check that the cold water pressure is sufficient for the water heater If ...

Page 12: ...e insulation of the fixed wiring must be protected by insulating sleeving having an appropriate temperature rating 6 If the supply cord is to be replaced this must be done by a service technician electrician or similarly qualified person in accordance with the wiring rules Weather proof power outlet Wiring diagram IG Elect rod Heater Thermostat Heater W Y B L O R FM Remote Controller 2 3 4 5 6 7 8...

Page 13: ...on or water heater the remote controller will display a numerical error code Main remote controller model KGCMRCA KGCMRCA must be installed inside as it is NOT water resistant Allows the output temperature from the water heater to be adjusted within the range of 37ºC to 55ºC The temperature options are 37ºC 38ºC 39ºC 40ºC 41ºC 42ºC 43ºC 44ºC 45ºC 46ºC 47ºC 50ºC 55ºC When BURNER ON lamp is lit the ...

Page 14: ... to attach the remote control to gyprock you should use the anchor plug use the fork terminals 25mm remote control wiring connector base 83 5mm 45mm warning The remote controller must be installed inside and in an area that isn t wet or damp as it is NOT water resistant This includes bathrooms and other potentially wet areas DO NOT position the remote controls in the vicinity of chemicals DO NOT p...

Page 15: ...connect remote control wires to remote terminals directly There is no polarity in the terminations plastic cover KGCMRCA typical cable layout remote control terminal remote control cable Remove the plastic cover and connect the terminals directly behind the cover Put the remote wires through the hole on the bottom of the unit s casing 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 caution DO NOT jump or short ci...

Page 16: ...e inlet to the water heater 7 Check the gas pipe work for leaks and stop the leaks as necessary caution If there is a gas leak that cannot be stopped do not try to start the water heater Do not touch any electrical switches use a mobile phone or any other ignition source Close the main gas isolating valve to the premises and walk a safe distance away Call the gas supplier and follow the gas suppli...

Page 17: ...en to be handed to the customer or left in a suitable location on the premises If the customer is available they are to be instructed on the safe and correct operating of the water heater and any auxiliary equipment If the hot water system isn t going to be used for a long time and needs to be turned off after commissioning follow these instructions Switch off the electrical supply at the power ou...

Page 18: ...to keep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature Is the filter on the cold water inlet clean Is the gas line sized properly Is the supply gas pressure enough Are the cold water and hot water lines cross connected Water heater Problem Possible solutio...

Page 19: ...the bottom left hand side of the cabinet and the error codes can be read from the LED on the PCB Error Codes on the PCB The LED on the PCB Symptom LED light blinks once Incorrect dipswitch setting gas Proportional valve computer LED light blinks twice Output thermistor Inlet thermistor Air fuel ratio rod failure LED light blinks three times Ignition failure Flame loss Abnormal main gas valve or ga...

Page 20: ...20 notes Kelvinator Gas Continuous Flow hot water system Notes ...

Page 21: ...Kelvinator Gas Continuous Flow hot water system notes 21 Notes ...

Page 22: ...22 notes Kelvinator Gas Continuous Flow hot water system Notes ...

Page 23: ... is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is dam...

Page 24: ...her information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: