warning

•    Contact an authorised installer for installation of this hot 

water system.

•    Contact an authorised service technician for repair or 

maintenance of this hot water system.

•   Installation work must be performed in accordance  
 

with national standards by suitably licensed installers  

 

only. Wrong connection can cause over heating or fire.

•   This hot water system should be installed in accordance 

with AS/NZS 3000 and your electricity suppliers rules.

For the installer

The installation must be done in accordance with the 
information supplied in the installation manual supplied  
with the hot water system. 
All other relevant National, State or Local regulations must 
also be conformed with and these include (but are not 
limited to): 
•  Australian Standard AS/NZS3500.1 - Water Supply
•  Australian Standard AS/NZS3500.4 - Hot Water Supply
•  Australian Standard AS/NZS3000 - Electrical Installations

warning

This heat pump hot water system is approved for connection 
to either continuous tariff or extended off peak tariff only 
(also referred to as off peak 2 tariff where there may be 
approximately 19 hours of power available per day). This  
heat pump is NOT suitable for connection to night rate 
tariff power supply (also referred to as off peak 1 where 
there may be approximately 8 hours of power available per 
day). Connecting to night rate power supply may cause the 
automatic sanitisation function to not always comply with 
Australian Standard AS 3498 for legionella control.

 

warning

This hot water system delivers water in excess of 50°C. 
Water temperatures above 50°C can cause severe burns, 
scalding or death. Feel the water temperature before 
bathing or showering. Do not leave children unsupervised. 
Under AS/NZS 3500 the temperature of the hot water 
being delivered must not exceed 50°C at any outlets used 
primarily for purposes of personal hygiene. To comply with 
these standards, a tempering valve set (supplied) must be 
fitted to this hot water system.

warning

 

Do not operate or stop the hot water system by 
switching on or off the power

Do not use a damaged or unspecified power  
supply cable 

Do not allow water to run into electric parts of  
the hot water system as it may cause failure or 
electric shock

 

Do not open any part of the hot water system during 
operation as it may cause electric shock

 

Do not store flammable gas or combustibles such as 
gasoline, benzene, paint thinner etc near the hot water 
system as this may cause corrosion or an explosion

Do not disassemble or modify the hot water system 
as it may cause failure and electric shock

 

Important safety instructions

Kelvinator heat pump hot water system   

important safety instructions  3

Summary of Contents for KCT27036A

Page 1: ...Heat Pump Hot Water System User Manual ...

Page 2: ...er system but contact your local Electrolux Customer Care Centre Meanings of symbols used in this manual are shown below warning This symbol indicates information concerning your personal safety caution This symbol indicates information on how to avoid damaging the hot water system environmental tips This symbol indicates tips and information about economical and ecological use of the hot water sy...

Page 3: ...off peak 1 where there may be approximately 8 hours of power available per day Connecting to night rate power supply may cause the automatic sanitisation function to not always comply with Australian Standard AS 3498 for legionella control warning This hot water system delivers water in excess of 50 C Water temperatures above 50 C can cause severe burns scalding or death Feel the water temperature...

Page 4: ...he heat pump and the warranty may be void if the heat pump is damaged as a result of freezing when there was no power available Ensure the following safety instructions are read and understood before using this hot water system warning Do not use this hot water system if it has at any stage been immersed in water Immediately call a licensed plumber gas fitter or authorised technician to inspect an...

Page 5: ...L KCT34036A 340L KCT34036B 425L KCT42536B Your heat pump hot water system components please tick Heat Pump KSE362HPCA Continuous power supply Extended off peak off peak 2 power supply System model number Heat pump serial number Storage tank serial number Installation date Installed by Notes System model number required to claim your STCs Heat pump model no Tank model no Power supply System model n...

Page 6: ... by taking heat energy from the surrounding air and then transferring the heat energy into water circulating from the hot water storage tank Since this energy is not created but simply moved and concentrated from one location to another it is a very efficient and cost effective when compared to a common electric hot water service Hot Water Storage Tank The hot water storage tank is where the hot w...

Page 7: ...ned of water to prevent damage due to freezing Follow the instructions on page 8 of this manual to safely drain and then re fill the hot water system as required Water quality Water quality can vary in different locations and affect the performance and safe operation of the hot water system If the water quality is not within the acceptable limits as indicated on this page the hot water system shou...

Page 8: ... activate the relief valve returning it to its normal position 10 Reconnect the inlet piping to the storage tank and then turn on the isolation valve located on the inlet piping to allow mains water to refill the tank 11 Turn on the nearest hot water tap to allow air to be expelled from the system Once water has begun to flow freely from the tap for a period of time and all air has been expelled f...

Page 9: ...er outlet connection is pointing away from any electrical components Bleed air from the water lines by twisting the knob on the valve anti clockwise Once water has begun flowing freely from the drainage tube for 10 seconds or more twist the knob clockwise to stop the valve from draining inlet outlet air bleed valve 13 Clean all filters in the hot water system including the tempering valve filters ...

Page 10: ...connected to this hole as part of the installation If an excessive amount of water is coming from this hole drainage pipe or anywhere else on the heat pump please call a service technician The sound of water flow inside the heat pump This is caused by the refrigerant and water flowing inside the heat pump It may be louder during the first few minutes of operation and is normal Short hissing sound ...

Page 11: ...d is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage excessive water pressure excessive inlet water temperature or incorrect power supply v incompl...

Page 12: ...ation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 136 226 fax 1800 350 067 email hotwatersystems electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: