background image

4  important safety instructions  

Kelvinator heat pump hot water system

caution

•  Do not use the hot water system for any other purposes 

besides heating water for domestic use.

•  Do not place items which might be damaged by moisture 

around the hot water system or near the drain outlets. 

•  If a power cable is damaged, it must be replaced by an 

Electrolux service agent or qualified persons in order to 
avoid a hazard.

•   This appliance is not intended for use by persons 

(including children) with reduced physical, sensory  
or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be 
supervised to ensure that they do not play with  
the appliance.

•  Water may drip from underneath the heat pump or from 

the heat pump condensation discharge pipe (if installed) 
during its heating cycle. Ensure that this water is drained to 
a suitable location, away from the footings of a building.

•  Water may drip from the discharge pipe of the pressure 

relief valve. This pipe must be left open to atmosphere at 
all times.

•  The pressure-relief device is to be operated regularly to 

remove lime deposits and to verify that it is not blocked.

•  A discharge pipe connected to the pressure-relief valve is 

to be installed in a continuously downward direction and 
in a frost-free environment.

•  If the heat pump is installed in a location that has the 

potential to drop below freezing point, the heat pump 
must be installed on continuous power supply only and 
the power supply must be connected at all times. The 
freeze protection system only works when power is 
connected to the heat pump and the warranty may be 
void if the heat pump is damaged as a result of freezing 
when there was no power available.

Ensure the following safety instructions are read and 
understood before using this hot water system.

warning

•  Do not use this hot water system if it has at any stage 

been immersed in water. Immediately call a licensed 
plumber, gas fitter or authorised technician to inspect 
and/or service the system.

•  In order to avoid electric shock, fire or injury, if any 

abnormality is detected, such as the smell of smoke 
coming from the hot water system, isolate the power at 
the main switchboard then contact your local Electrolux 
Customer Care Centre.

•  Do not insert fingers, rods or other objects into the air 

inlet or outlet of the heat pump. If the fan is rotating, it 
may cause personal injury or damage.

•  Do not remove any guards or panels on the heat pump. 

It may cause a safety hazard or allow the unit to be 
damaged.

•  Do not touch the heat exchanger fins. These fins are sharp 

and could result in cutting injuries.

•  Never use a flammable spray such as hair spray, lacquer 

or paint near the hot water system as it may cause a fire.

•  If the heat pump has been installed on a stand or wall 

brackets, periodically check the stand, brackets and 
fittings. If damaged or loose, the heat pump may fall and 
result in injury.

•  The operation of the thermal cut out (located on the 

storage tank thermostat) indicates a possibly dangerous 
situation. Do not reset the thermal cut out until the water 
heater has been serviced by a qualified person.

•  If power to the hot water system has been turned off 

for an extended period of time e.g. holidays, prolonged 
blackout or maintenance, it is recommended that the 
auxiliary heating boost function be activated once  
power is available. This will ensure that the hot water  
is sufficiently sanitised for household usage.

Important safety instructions

Summary of Contents for KCT27036A

Page 1: ...Heat Pump Hot Water System User Manual ...

Page 2: ...er system but contact your local Electrolux Customer Care Centre Meanings of symbols used in this manual are shown below warning This symbol indicates information concerning your personal safety caution This symbol indicates information on how to avoid damaging the hot water system environmental tips This symbol indicates tips and information about economical and ecological use of the hot water sy...

Page 3: ...off peak 1 where there may be approximately 8 hours of power available per day Connecting to night rate power supply may cause the automatic sanitisation function to not always comply with Australian Standard AS 3498 for legionella control warning This hot water system delivers water in excess of 50 C Water temperatures above 50 C can cause severe burns scalding or death Feel the water temperature...

Page 4: ...he heat pump and the warranty may be void if the heat pump is damaged as a result of freezing when there was no power available Ensure the following safety instructions are read and understood before using this hot water system warning Do not use this hot water system if it has at any stage been immersed in water Immediately call a licensed plumber gas fitter or authorised technician to inspect an...

Page 5: ...L KCT34036A 340L KCT34036B 425L KCT42536B Your heat pump hot water system components please tick Heat Pump KSE362HPCA Continuous power supply Extended off peak off peak 2 power supply System model number Heat pump serial number Storage tank serial number Installation date Installed by Notes System model number required to claim your STCs Heat pump model no Tank model no Power supply System model n...

Page 6: ... by taking heat energy from the surrounding air and then transferring the heat energy into water circulating from the hot water storage tank Since this energy is not created but simply moved and concentrated from one location to another it is a very efficient and cost effective when compared to a common electric hot water service Hot Water Storage Tank The hot water storage tank is where the hot w...

Page 7: ...ned of water to prevent damage due to freezing Follow the instructions on page 8 of this manual to safely drain and then re fill the hot water system as required Water quality Water quality can vary in different locations and affect the performance and safe operation of the hot water system If the water quality is not within the acceptable limits as indicated on this page the hot water system shou...

Page 8: ... activate the relief valve returning it to its normal position 10 Reconnect the inlet piping to the storage tank and then turn on the isolation valve located on the inlet piping to allow mains water to refill the tank 11 Turn on the nearest hot water tap to allow air to be expelled from the system Once water has begun to flow freely from the tap for a period of time and all air has been expelled f...

Page 9: ...er outlet connection is pointing away from any electrical components Bleed air from the water lines by twisting the knob on the valve anti clockwise Once water has begun flowing freely from the drainage tube for 10 seconds or more twist the knob clockwise to stop the valve from draining inlet outlet air bleed valve 13 Clean all filters in the hot water system including the tempering valve filters ...

Page 10: ...connected to this hole as part of the installation If an excessive amount of water is coming from this hole drainage pipe or anywhere else on the heat pump please call a service technician The sound of water flow inside the heat pump This is caused by the refrigerant and water flowing inside the heat pump It may be louder during the first few minutes of operation and is normal Short hissing sound ...

Page 11: ...d is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage excessive water pressure excessive inlet water temperature or incorrect power supply v incompl...

Page 12: ...ation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 136 226 fax 1800 350 067 email hotwatersystems electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: