background image

Service and Installation Manual

 

10 

MAINTENANCE                                                                                                                                     

Cleaning solutions need to be alkaline based or non-chloride based.    Any cleaner containing chlorides will 
damage the protective film of the stainless steel. Chlorides are commonly found in hard water, salts, and 
household and industrial cleaners. If cleaners containing chlorides are used, be sure to rinse repeatedly and 
dry thoroughly. 

Routine  cleaning  of  stainless  steel  can  be  done  with  soap  and  water.  Extreme  stains  or  grease  should  be 
cleaned with a non-abrasive cleaner and plastic scrub pad. It is always good to rub with the grain of the steel. 
There  are  also  stainless  steel  cleaners  available  which  can  restore  and  preserve  the  finish  of  the  steels 
protective layer. 

Early  signs  of  stainless  steel  breakdown  can  consist  of  small  pits  and  cracks.  If  this  has  begun,  clean 
thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel. 

 

Gasket Maintenance 

Gaskets require regular cleaning to prevent mold and mildew build up and also to keep the elasticity of 
the gasket. Gasket cleaning can be done with the use of warm soapy water.    Avoid full strength 
cleaning products on gaskets as this can cause them to become brittle and prevent proper seals. Do not 
use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the 
bellows. 

Gaskets can easily be replaced and don’t require the use of tools or authorized service technicians.    The 
gaskets are "Dart" style and can be pulled out of the grove in the door and replaced by pressing the new one 
back into place. 

Doors/Hinges 

Over time and with heavy use, door hinges may become loose. If the door is beginning to sag, tighten 
the screws that mount the hinge brackets to the frame of the unit. If the doors are loose or sagging this 
can cause the hinge to pull out of the frame which may damage to both the doors and the door hinges.   

Drain Maintenance 

Each unit has a drain located inside the unit which removes the condensation from the evaporator coil and 
evaporates it into an external condensate evaporator pan. Each drain can become loose or disconnected 
from moving or bumping the drain. If you notice excessive water accumulation on the inside of the unit, be 
sure the drain tube is connected from the evaporator housing to the condensate evaporator drain pan. If 
water starts to collect underneath the unit, you may want to check the condensate evaporator drain tube to 
be sure it is still located inside the drain pan. The leveling of the unit is important as the units are designed to 
drain properly when on a level surface. If your floor is not level this can also cause drain problems. Be sure 
all drain lines are free of obstructions because this may cause water to back up and overflow the drain pans. 

 
 

 
 

 
 
 

 

Never use an acid based cleaning solution

Many food products have an acidic content 

which can deteriorate the finish. Be sure to clean the stainless steel surfaces of ALL 
food products.   

Summary of Contents for KCHGM12R

Page 1: ...rvice Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...if the instructions are not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction conc...

Page 3: ...érant ou le congélateur doivent éviter les dommages du tuyau réfrigérant ou le rique de la fuite Caution Risk of Fire or Explosion due to Flammable Refrigerant Used Follow Handling Instructions Carefully in Compliance with U S Government Regulations Component parts shall be replaced with like components and that servicing shall be done by factory authorized service personnel so as to minimize the ...

Page 4: ...hough most equipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged ...

Page 5: ...1 5 15P SWING GLASS DOOR FREEZERS MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP BTU CHARGE OZ SHIP WEIGHT LBS NEMA PLUG KCHGM26F 115 60 1 8 0 24 1 2 2000 3 88 360 5 15P KCHGM48F 115 208 230 60 1 6 5 48 1 3650 5 29 567 KCHGM72F 115 208 230 60 1 9 0 5 29 72 4500 829 L14 20P 1 1 4 L14 20P SLIDING GLASS DOOR REFRIGERATORS MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP BTU CHARGE OZ SHIP WEIGHT LBS NEMA P...

Page 6: ...uld it become necessary to lay the unit on its side or back for any reason allow at least 24 hours before start up so as to allow compressor oil to flow back to the sump Failure to meet this requirement can cause compressor failure and unit damage Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly the cabinet will not be subject to...

Page 7: ... defrost heater will work to clear up the ice The controller now displays the defrost symbol When the coil temperature reaches 45 F or after 20 minutes of defrost the unit will turn on again 1 Anti Condensation heaters on the door frames work in conjunction with the compressor 2 The factory setting of the temperature range is 7 F to 3 F Light Switch A light switch is located next to the on off swi...

Page 8: ...s 2 The POF message will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3s the POF message will be displayed 2 5 HOW TO UNLOCK THE KEYBOARD Hold the and keys together for more than 3s till the POF message is displayed 3 ALARM SIGNALS HOW TO SEE THE ALARM AND RESET THE RECO...

Page 9: ...a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor or cost to replace the compressor Never use a high pressure water wash for this cleaning procedure as water can dama...

Page 10: ...eplaced and don t require the use of tools or authorized service technicians The gaskets are Dart style and can be pulled out of the grove in the door and replaced by pressing the new one back into place Doors Hinges Over time and with heavy use door hinges may become loose If the door is beginning to sag tighten the screws that mount the hinge brackets to the frame of the unit If the doors are lo...

Page 11: ... bottom hinge pin Sliding Door Replacement and Adjustment 1 Take off the hook of the counterweight of door from the top of the door 2 Hold the door up until the bottom edge is over the channel Move the door out across the channel and lay the door down 3 Prepare new door hold the door insert into top channel until the bottom edge is over the bottom channel Slide the bottom of the door across the ch...

Page 12: ...Service and Installation Manual 12 WIRING DIAGRAM MODEL KCHGM12R MODEL KCHGM26R ...

Page 13: ...Service and Installation Manual 13 WIRING DIAGRAM MODEL KCHGM48R MODEL KCHGM72R ...

Page 14: ...Service and Installation Manual 14 WIRING DIAGRAM MODEL KCHGM26F MODEL KCHGM48F ...

Page 15: ...Service and Installation Manual 15 WIRING DIAGRAM MODEL KCHGM72F MODEL KCHSGM36R ...

Page 16: ...Service and Installation Manual 16 WIRING DIAGRAM MODEL KCHSGM48R MODEL KCHSGM72R ...

Page 17: ...Service and Installation Manual 17 WIRING DIAGRAM MODEL KCHGM12R ...

Page 18: ...Service and Installation Manual 18 WIRING DIAGRAM MODEL KCHGM26R ...

Page 19: ...Service and Installation Manual 19 WIRING DIAGRAM MODEL KCHGM48R ...

Page 20: ...Service and Installation Manual 20 WIRING DIAGRAM MODEL KCHGM72R ...

Page 21: ...Service and Installation Manual 21 WIRING DIAGRAM MODEL KCHSGM36R ...

Page 22: ...Service and Installation Manual 22 WIRING DIAGRAM MODEL KCHSGM48R ...

Page 23: ...Service and Installation Manual 23 WIRING DIAGRAM MODEL KCHSGM72R ...

Page 24: ...Service and Installation Manual 24 WIRING DIAGRAM MODEL KCHGM26F ...

Page 25: ...Service and Installation Manual 25 WIRING DIAGRAM MODEL KCHGM48F ...

Page 26: ...Service and Installation Manual 26 WIRING DIAGRAM MODEL KCHGM72F ...

Page 27: ...mages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God 15 For appliances operated by a concessionaire or vendor in a trailer or other motorized vehicle or at varying locat...

Page 28: ...s suelo gabinetes paredes etc 14 Daños provocados por servicios técnicos realizados por empresas de servicio no autorizadas uso de piezas que no sean las piezas genuinas de Electrolux o piezas obtenidas de personas que no sean las empresas de servicio técnico autorizado o causas externas como abuso uso incorrecto suministro de alimentación inadecuado accidentes incendios o casos fortuitos 15 Para ...

Page 29: ...s dommages causés par des réparations faites par des techniciens non autorisés l utilisation de pièces autres que les pièces Electrolux d origine ou des pièces qui n ont pas été obtenues par l entremise d un réparateur autorisé ou des causes externes comme l usage abusif le mauvais usage l emploi d une alimentation électrique inadéquate les accidents les incendies ou les catastrophes naturelles 15...