Kelvinator KCHGM12R Service, Installation And Care Manual Download Page 6

Service and Installation Manual

 

INSTALLATION                                                                                                                                     

Location 

Units represented in this manual are intended for indoor use only.    Be sure the location chosen has a floor 
strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much as 
1500 pounds. Reinforce the floor as necessary to provide for maximum loading. For the most efficient 
refrigeration, be sure to provide good air circulation inside and out. 

 
Inside cabinet: 

Do not pack refrigerator so full that air cannot circulate. The refrigerated air is discharged at the top rear of the 
unit. It is important to allow for proper air flow from the top rear to the bottom of the unit. Obstructions to this air 
flow can cause evaporator coil freeze ups and loss of temperature or overflow of water from the evaporator drain 
pan. The shelves have a rear turn up on them to prevent this. However, bags and other items can still be located 
to the far rear of the cabinet. Air is brought into the evaporator coil with fans mounted to the front of the coil. 
Prevent obstruction by locating large boxes and tall stacks of product to the bottom of the cabinet. 

 
Outside cabinet:

   

Be sure that the unit has access to ample air. Avoid hot corners and locations near stoves and ovens. 
It is recommended that the unit be installed no closer than 2" from any wall with at least 12" of clear space above 
the unit. Should it become necessary to lay the unit on its side or back for any reason, allow at least 24 hours 
before start-up so as to allow compressor oil to flow back to the sump. Failure to meet this requirement can 
cause compressor failure and unit damage. 

 
Leveling 

A level cabinet looks better and will perform better because the doors will line up with the frames properly, the 
cabinet will not be subject to undue strain and the contents of the cabinet will not move around on the shelves. 
Use a level to make sure the unit is level from front to back and side to side. Units supplied with legs will have 
adjustable bullet feet to make the necessary adjustments. If the unit is supplied with casters, no adjustments are 
available. Ensure the floor where the unit is to be located is level. 

 
Stabilizing 

Models are supplied on casters for your convenience, ease of cleaning underneath and for mobility. It is very 
important, however, that the cabinet be installed in a stable condition with the front wheels locked while in use. 

 
 

Standard warranties will be voided due to improper installation procedures. 

 

Electrical connection

 

Refer to the amperage data on page 3, the serial tag, your local code or the National Electrical Code to be sure 
the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must 
be run for connection of the line cord, or permanent connection to the unit. 
 

 

The ON/OFF switch must be turned to OFF and the unit disconnected from the power 
source whenever performing service, maintenance functions or cleaning the refrigerated 
area. 

 

 

 

 

Summary of Contents for KCHGM12R

Page 1: ...rvice Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...if the instructions are not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction conc...

Page 3: ...érant ou le congélateur doivent éviter les dommages du tuyau réfrigérant ou le rique de la fuite Caution Risk of Fire or Explosion due to Flammable Refrigerant Used Follow Handling Instructions Carefully in Compliance with U S Government Regulations Component parts shall be replaced with like components and that servicing shall be done by factory authorized service personnel so as to minimize the ...

Page 4: ...hough most equipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged ...

Page 5: ...1 5 15P SWING GLASS DOOR FREEZERS MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP BTU CHARGE OZ SHIP WEIGHT LBS NEMA PLUG KCHGM26F 115 60 1 8 0 24 1 2 2000 3 88 360 5 15P KCHGM48F 115 208 230 60 1 6 5 48 1 3650 5 29 567 KCHGM72F 115 208 230 60 1 9 0 5 29 72 4500 829 L14 20P 1 1 4 L14 20P SLIDING GLASS DOOR REFRIGERATORS MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP BTU CHARGE OZ SHIP WEIGHT LBS NEMA P...

Page 6: ...uld it become necessary to lay the unit on its side or back for any reason allow at least 24 hours before start up so as to allow compressor oil to flow back to the sump Failure to meet this requirement can cause compressor failure and unit damage Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly the cabinet will not be subject to...

Page 7: ... defrost heater will work to clear up the ice The controller now displays the defrost symbol When the coil temperature reaches 45 F or after 20 minutes of defrost the unit will turn on again 1 Anti Condensation heaters on the door frames work in conjunction with the compressor 2 The factory setting of the temperature range is 7 F to 3 F Light Switch A light switch is located next to the on off swi...

Page 8: ...s 2 The POF message will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3s the POF message will be displayed 2 5 HOW TO UNLOCK THE KEYBOARD Hold the and keys together for more than 3s till the POF message is displayed 3 ALARM SIGNALS HOW TO SEE THE ALARM AND RESET THE RECO...

Page 9: ...a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor or cost to replace the compressor Never use a high pressure water wash for this cleaning procedure as water can dama...

Page 10: ...eplaced and don t require the use of tools or authorized service technicians The gaskets are Dart style and can be pulled out of the grove in the door and replaced by pressing the new one back into place Doors Hinges Over time and with heavy use door hinges may become loose If the door is beginning to sag tighten the screws that mount the hinge brackets to the frame of the unit If the doors are lo...

Page 11: ... bottom hinge pin Sliding Door Replacement and Adjustment 1 Take off the hook of the counterweight of door from the top of the door 2 Hold the door up until the bottom edge is over the channel Move the door out across the channel and lay the door down 3 Prepare new door hold the door insert into top channel until the bottom edge is over the bottom channel Slide the bottom of the door across the ch...

Page 12: ...Service and Installation Manual 12 WIRING DIAGRAM MODEL KCHGM12R MODEL KCHGM26R ...

Page 13: ...Service and Installation Manual 13 WIRING DIAGRAM MODEL KCHGM48R MODEL KCHGM72R ...

Page 14: ...Service and Installation Manual 14 WIRING DIAGRAM MODEL KCHGM26F MODEL KCHGM48F ...

Page 15: ...Service and Installation Manual 15 WIRING DIAGRAM MODEL KCHGM72F MODEL KCHSGM36R ...

Page 16: ...Service and Installation Manual 16 WIRING DIAGRAM MODEL KCHSGM48R MODEL KCHSGM72R ...

Page 17: ...Service and Installation Manual 17 WIRING DIAGRAM MODEL KCHGM12R ...

Page 18: ...Service and Installation Manual 18 WIRING DIAGRAM MODEL KCHGM26R ...

Page 19: ...Service and Installation Manual 19 WIRING DIAGRAM MODEL KCHGM48R ...

Page 20: ...Service and Installation Manual 20 WIRING DIAGRAM MODEL KCHGM72R ...

Page 21: ...Service and Installation Manual 21 WIRING DIAGRAM MODEL KCHSGM36R ...

Page 22: ...Service and Installation Manual 22 WIRING DIAGRAM MODEL KCHSGM48R ...

Page 23: ...Service and Installation Manual 23 WIRING DIAGRAM MODEL KCHSGM72R ...

Page 24: ...Service and Installation Manual 24 WIRING DIAGRAM MODEL KCHGM26F ...

Page 25: ...Service and Installation Manual 25 WIRING DIAGRAM MODEL KCHGM48F ...

Page 26: ...Service and Installation Manual 26 WIRING DIAGRAM MODEL KCHGM72F ...

Page 27: ...mages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God 15 For appliances operated by a concessionaire or vendor in a trailer or other motorized vehicle or at varying locat...

Page 28: ...s suelo gabinetes paredes etc 14 Daños provocados por servicios técnicos realizados por empresas de servicio no autorizadas uso de piezas que no sean las piezas genuinas de Electrolux o piezas obtenidas de personas que no sean las empresas de servicio técnico autorizado o causas externas como abuso uso incorrecto suministro de alimentación inadecuado accidentes incendios o casos fortuitos 15 Para ...

Page 29: ...s dommages causés par des réparations faites par des techniciens non autorisés l utilisation de pièces autres que les pièces Electrolux d origine ou des pièces qui n ont pas été obtenues par l entremise d un réparateur autorisé ou des causes externes comme l usage abusif le mauvais usage l emploi d une alimentation électrique inadéquate les accidents les incendies ou les catastrophes naturelles 15...

Reviews: