background image

BEER DISPENSERS

INSTALLATION

NOTE: 

STANDARD WARRANTIES WILL BE VOIDED DUE TO IMPROPER 

INSTALLATION PROCEDURES.

DANGER:  THE ON/OFF SWITCH MUST BE TURNED TO OFF AND THE UNIT 

DISCONNECTED FROM THE POWER SOURCE WHENEVER PERFORMING 

SERVICE, MAINTENANCE FUNCTIONS OR CLEANING THE REFRIGERATED 

AREA.

LOCATION

Units represented in this manual are intended for indoor use only. Be sure the 
location chosen has a floor strong enough to support the total weight of the cabinet 
and contents. A fully loaded unit can weigh as much as 1500 pounds. Reinforce 
the floor as necessary to provide for maximum loading. For the most efficient 
refrigeration, be sure to provide good air circulation inside and out.

OUTSIDE CABINET

Be sure that the unit has access to ample air. Avoid hot corners and locations near 
stoves and ovens. It is recommended that the unit be installed no closer than 2” 
from any wall with at least 12” of clear space above the unit. Should it become 
necessary to lay the unit on its side or back for any reason, allow at least 24 hours 
before start-up so as to allow compressor oil to flow back to the sump. Failure to 
meet this requirement can cause compressor failure and unit damage.

IMPORTANT - READ FIRST - IMPORTANT

YOUR SAFETY AND THE SAFETY OF OTHERS ARE VERY IMPORTANT.
WE HAVE PROVIDED MANY IMPORTANT SAFETY MESSAGES IN THIS MANUAL AND ON YOUR 

APPLIANCE. ALWAYS READ AND OBEY ALL SAFETY MESSAGES.
OUR PRODUCT INSTRUCTIONS WILL BE UPLOADED ON OUR COMPANY OFFICIAL WEBSITE.
 

  THIS IS THE SAFETY ALERT SYMBOL. THIS SYMBOL ALERTS YOU TO POTENTIAL 

HAZARDS THAT CAN KILL OR INJURE YOU AND OTHERS. ALL SAFETY MESSAGES 

WILL FOLLOW THE SAFETY ALERT SYMBOL AND EITHER THE WORDS” DANGER”, 

“WARNING” OR “CAUTION”.

 

  DANGER MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT 

IN SEVERE PERSONAL INJURY OR DEATH.

 

  WARNING MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY 

RESULT IN EXTENSIVE PRODUCT DAMAGE, SERIOUS PERSONAL INJURY, OR 

DEATH.

 

  CAUTION MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT 

IN MINOR OR MODERATE PERSONAL INJURY, OR PROPERTY OR EQUIPMENT 

DAMAGE.

ALL SAFETY MESSAGES WILL ALERT YOU TO WHAT THE POTENTIAL HAZARD IS, TELL YOU 

HOW TO REDUCE THE CHANCE OF INJURY, AND LET YOU KNOW WHAT CAN HAPPEN IF THE 

INSTRUCTIONS ARE NOT FOLLOWED.
FOLLOW BASIC PRECAUTIONS, INCLUDING THE FOLLOWING:
NOTE:    IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE 

MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN 

ORDER TO AVOID A HAZARD. 

NOTE:    THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING 

CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, 

OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN 

SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A 

PERSON RESPONSIBLE FOR THEIR SAFETY.

NOTE: 

  CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH 

THE APPLIANCE.

NOTE: 

  THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE 

AND PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES 

OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN 

SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE 

WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY 

WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE SHALL NOT BE 

MADE BY CHILDREN WITHOUT SUPERVISION.

NOTE:    KEEP THE APPLIANCE AND ITS CORD OUT OF REACH OF CHILDREN LESS THAN 8 

YEARS.

NOTE:    DO NOT STORE EXPLOSIVE SUBSTANCES SUCH AS AEROSOL CANS WITH A 

FLAMMABLE PROPELLANT IN THIS APPLIANCE.

NOTE:    THE APPLIANCE USE FLAMMABLE INSULATION BLOWING GAS C5H10, DISPOSAL 

OF THE APPLIANCE SHALL IN ACCORDANCE WITH THE REGULATIONS OF LOCAL 

AUTHORITIES.

NOTE:    THE KEY FOR APPLIANCE ELECTRIC BOX SHOULD BE SAFE KEPT BY QUALIFIED 

PERSONS IN ORDER TO AVOID A HAZARD 

WARNING:   KEEP VENTILATION OPENINGS, IN THE APPLIANCE ENCLOSURE OR IN THE BUILT-IN 

STRUCTURE, CLEAR OF OBSTRUCTION.

WARNING:  DO NOT USE MECHANICAL DEVICES OR OTHER MEANS TO ACCELERATE 

THE DEFROSTING PROCESS, OTHER THAN THOSE RECOMMENDED BY THE 

MANUFACTURER.

WARNING:   DO NOT DAMAGE THE REFRIGERANT CIRCUIT.
WARNING:   DO NOT USE ELECTRICAL APPLIANCES INSIDE THE FOOD STORAGE COMPARTMENTS 

OF THE APPLIANCE, UNLESS THEY ARE OF THE TYPE RECOMMENDED BY THE 

MANUFACTURER. HANDLING, MOVING, AND USE OF THE REFRIGERATOR OR 

FREEZER TO AVOID EITHER DAMAGING THE REFRIGERANT TUBING, OR INCREASING 

THE RISK OF A LEAK.

CAUTION:   RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH U.S. GOVERNMENT 

REGULATIONS. COMPONENT PARTS SHALL BE REPLACED WITH LIKE COMPONENTS 

AND THAT SERVICING SHALL BE DONE BY FACTORY AUTHORIZED SERVICE 

PERSONNEL, SO AS TO MINIMIZE THE RISK OF POSSIBLE IGNITION DUE TO 

INCORRECT PARTS OR IMPROPER SERVICE.

CAUTION:   RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED

DANGER:    RISK OF CHILD ENTRAPMENT. BEFORE YOU THROW AWAY YOUR OLD REFRIGERATOR 

OR FREEZER: TAKE OFF THE DOORS, LEAVE THE SHELVES IN PLACE SO THAT 

CHILDREN MAY NOT EASILY CLIMB INSIDE.

LEVELING

A level cabinet looks better and will perform better because the doors will line up 
with the frames properly, the cabinet will not be subject to undue strain and the 
contents of the cabinet will not move around on the shelves. Use a level to make 
sure the unit is level from front to back and side to side. Units supplied with legs 
will have adjustable bullet feet to make the necessary adjustments. If the unit is 
supplied with casters, no adjustments are available. Ensure the floor where the 
unit is to be located is level.

STABILIZING

Models are supplied on casters for your convenience, ease of cleaning underneath 
and for mobility. It is very important, however, that the cabinet be installed in a 
stable condition with the front wheels locked while in use.

ELECTRICAL CONNECTION

Refer to the amperage data on page 5, the serial tag, your local code or the National 
Electrical Code to be sure the unit is connected to the proper power source. A 
protected circuit of the correct voltage and amperage must be run for connection 
of the line cord, or permanent connection to the unit.

Summary of Contents for KCHBBD1D1T

Page 1: ...known to be current and accurate at the time of printing creation Reference our product line website for the most updated product information and specifications 2023 Electrolux Professional Inc All R...

Page 2: ...CAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOL...

Page 3: ...for more than 2 seconds to change the set point value 2 The value of the set point will be displayed and the LED starts blinking 3 To change the set value push the or key within 10 seconds 4 To set n...

Page 4: ...elements can begin to breakdown the steel and begin to form rust of discoloration Proper cleaning of stainless steel requires soft cloths or plastic scouring pads Cleaning solutions need to be alkalin...

Page 5: ...the top of the draft arm Replace top cover 4 The air hose clip will assure that the hose remains in proper place at all times keeping the beer faucet cold ONE DOOR C02 KNOCK OUT This instruction is t...

Page 6: ...PARTS LIST CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515 Item Description 1 BEER KEG 2 D SHARP KEG TAP 3 BEER LINE 4 BEER DISPENSER 5 CO2 LINE 6 CO2 TEE JOINT 7 CO2 REGULATOR 8 CO2 CYLINDER 9 CO2 LI...

Page 7: ...ARTS 866 339 8515 Wiring Diagram KCHBBD2D1T KCHBBD2D2T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515 POWER PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CIRCULATION FAN MOTOR M M CONDENSER FAN MOTOR OVER...

Page 8: ...8 BEER DISPENSERS Wiring Diagram KCHBBD3D2T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...

Page 9: ...9 BEER DISPENSERS Wiring Diagram KCHBBD1D1T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...

Page 10: ...10 BEER DISPENSERS Wiring Diagram KCHBBD2D1T KCHBBD2D2T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...

Page 11: ...11 BEER DISPENSERS Wiring Diagram KCHBBD3D2T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...

Page 12: ...companies use of parts other than genuine Electrolux Professional Inc parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate p...

Page 13: ...13 BEER DISPENSERS Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 14: ...actual y exacta en el momento de su impresi n creaci n Consulte el sitio web de nuestra l nea de productos para obtener la informaci n y las especificaciones m s actualizadas 2023 Electrolux Professio...

Page 15: ...M S DE 8 A OS Y PERSONAS CON CAPACIDADES F SICAS SENSORIALES O MENTALES REDUCIDAS O QUE CAREZCAN DE EXPERIENCIA Y CONOCIMIENTOS SI SE LES SUPERVISA O SE LES INSTRUYE EN EL USO SEGURO DEL EQUIPO Y SI...

Page 16: ...el ajuste de referencia 1 Presione la tecla SET durante m s de 2 segundos para cambiar el valor del ajuste de referencia 2 Se muestra el valor del ajuste de referencia y el LED empieza a parpadear 3...

Page 17: ...ABLE Para evitar la decoloraci n causada por el xido en el acero inoxidable es necesario llevar a cabo varios pasos importantes Primero es esencial conocer las propiedades del acero inoxidable El acer...

Page 18: ...oma sobre los orificios de montaje del brazo de tiro en el armario introduzca el conector del conducto de cerveza por el orificio 2 A continuaci n fije el brazo de tiro con cuatro tornillos 3 Inserte...

Page 19: ...ECESITA REPUESTOS 866 339 8515 Elemento Descripci n 1 BARRIL DE CERVEZA 2 GRIFO DE BARRIL AFILADO EN D 3 CONDUCTO DE CERVEZA 4 DISPENSADOR DE CERVEZA 5 CONDUCTO DE CO2 6 UNI N EN T DE CO2 7 REGULADOR...

Page 20: ...ENSOR MOTOR DEL VENTILADOR DE CIRCULACI N M M MOTOR DEL VENTILADOR DEL CONDENSADOR PROTECCI N CONTRA SOBRECARGA COMPRESOR CONDENSADOR DE FUNCIONAMIENTO REL DE CORRIENTE CONDENSADOR DE ARRANQUE L N ENC...

Page 21: ...S 866 339 8515 ENCHUFE DE ALIMENTACI N EL CTRICA PANTALLA DEL TERMOSTATO SALA EVAP SENSOR CONDENSADOR DE ARRANQUE PROTECCI N CONTRA SOBRECARGA COMPRESOR CONDENSADOR DE FUNCIONAMIENTO REL DE CORRIENTE...

Page 22: ...TOS 866 339 8515 SENSOR DE TEMPERATURA EVAP SALA PANTALLA DEL TERMOSTATO NEGRO BLANCO VERDE AZUL MARR N NEGRO BLANCO VERDE NEGRO BLANCO VERDE AZUL MARR N NEGRO BLANCO VERDE MOTOR DEL VENTILADOR DE CIR...

Page 23: ...BBD2D2T LLAME A LA F BRICA SI NECESITA REPUESTOS 866 339 8515 VENTILADOR DEL EVAPORADOR COMPRESOR VENTILADOR DEL CONDENSADOR ENCHUFE TIERRA TIERRA INTERRUPTOR DE LA PUERTA INTERRUPTOR DE LA PUERTA PAN...

Page 24: ...F BRICA SI NECESITA REPUESTOS 866 339 8515 VENTILADOR DEL EVAPORADOR COMPRESOR VENTILADOR DEL CONDENSADOR ENCHUFE TIERRA TIERRA INTERRUPTOR DE LA PUERTA INTERRUPTOR DE LA PUERTA PANTALLA DEL TERMOSTA...

Page 25: ...dos de personas que no sean empresas de servicios autorizadas o causas externas como uso incorrecto o indebido alimentaci n el ctrica inadecuada accidentes incendios o desastres naturales 15 Los equip...

Page 26: ...S DE CERVEZA Registro de servicio N de modelo Adquirido a N de serie Ubicaci n Fecha de compra Fecha de instalaci n N de orden de compra Para llamadas al servicio t cnico Fecha Mantenimiento realizado...

Reviews: