3
BEER DISPENSERS
OPERATION
CAUTION: DO NOT THROW ITEMS INTO THE STORAGE AREA. FAILURE TO HEED THESE
RECOMMENDATIONS COULD RESULT IN DAMAGE TO THE INTERIOR OF THE
CABINET.
REFRIGERATORS
The factory setting for temperature range is 34°F - 38°F.
CONTROL PANEL SOLID-STATE THERMOSTAT
FRONT PANEL COMMANDS
SET
SET: To display target set point; in programming mode it selects a
parameter or confirm an operation..
DEF: To start a manual defrost
UP: To see the last temperature alarm happened; in programming mode it
browses the parameter codes or increases the display value
DOWN: To see the last temperature alarm happened; in programming
mode it browses the parameter codes or decreases the display value
Key Combination:
To lock & unlock the keyboard
To enter in programming mode
To return to the room temperature display
LED
MODE
FUNCTION
On
Compressor enabled
Flashing Anti short cycle delay enabled (AC parameter)
On
Defrost enabled
Flashing Dripping in progress
On
Measurement unit
Flashing Programming mode
On
Measurement unit
Flashing Programming mode
MAIN FUNCTIONS
1. How to See the Setpoint
1. Push and immediately release the
SET
key: the display will show the set
point value.
2. Push and immediately release the
SET
key or wait for 5 seconds to display
the sensor value again.
2. How to Change the Setpoint
1. Hold
the
SET
key for more than 2 seconds to change the set point value.
2. The value of the set point will be displayed and the
LED starts blinking.
3. To change the set value, push the or key within 10 seconds.
4. To set new point value, push the
SET
key again or wait 10 seconds.
3. How to Start a Manual Defrost
1. Hold the
key for more than 2 seconds and a manual defrost will start.
4. How to Lock the Keyboard
1. Hold the and keys for more than 3 seconds.
2. The “POF” message will be displayed and the keyboard will be locked. At
this point, it will be possible only to see the set point or the MAX or MIN
temperature stored.
3. If a key is pressed for more than 3 seconds, the ”POF” message will be
displayed.
5. How to Unlock the Keyboard
1. Hold the and keys together for more than 3 seconds, until the “POF”
message is displayed then press or key to select the item to check or
program.
ALARM SIGNALS
How to See the Alarm and Reset the Recorded Alarm
1. Push the or key to display the alarm signals.
2. When the signal is displayed, hold the
SET
key until the “rst” message is
displayed. Push the
SET
key again. The “rst” message starts blinking and the
normal temperature will be displayed again.
MESSAGE
CAUSE
OUTPUTS
“P1”
Room probe failure
Compressor output according
to “Cy” and “Cn”
“P2”
Evaporator probe failure
Defrost end is timed
(Only XR04CX)
“HA”
Maximum temperature alarm
Outputs unchanged
“LA”
Minimum temperature alarm
Outputs unchanged
“EA”
External alarm
Output unchanged
“CA”
Serious external alarm
All outputs OFF
“dA”
Door Open
Compressor and fans restarts
Summary of Contents for KCHBBD1D1T
Page 8: ...8 BEER DISPENSERS Wiring Diagram KCHBBD3D2T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...
Page 9: ...9 BEER DISPENSERS Wiring Diagram KCHBBD1D1T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...
Page 11: ...11 BEER DISPENSERS Wiring Diagram KCHBBD3D2T CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...